14.Assemblingtheheatexchanger
Swivellingthecombustionchamberinwards
Push the combustion chamber into the condensate pan.
Make sure the seal is seated securely in the groove.
Push the gas connection pipe downwards until it
engages.
The O-ring seal must no longer be visible.
Insertplugattheignitiontransformer.
Insert both plugs on the gas fan.
Check electrical connections for tightness.
Secure the locking clip on the rotary joint.
Checkthepressureindicatorintheappliance.
Top up with heating water if required.
Set pressure 2 - 2.5 bar.
Check the safety valve.
Cleanresiduesfromthetrap.
Then ll the trap with tap water, make sure it
engages and tighten the screws.
Check for secure seating - prevent ue gas escaping.
Operating the appliance with an empty trap presents a
risk of poisoning due to ue gases escaping.