DT10RF OPTIMISING PROGRAMMER
INSTRUCTION MANUAL
8 716 115 494a (02.2009)
OPERATING & INSTALLATION
INSTRUCTIONS
31
Installer
Options
Function Select
Option
Default
02 Freeze protection On Off On
Installer Options
1. If you wish to change any of the Installer Options
as shown in the table below, enter the Installer
Option Menu from Auto mode by pressing:
< and + simultaneously for 5 seconds.
Pressing < and + again for 5 seconds will exit the
Menu and return to Auto mode.
Once the Installer Options screen has been selected,
the < and > buttons allow you to scroll through
the Menu (shown below). The + and - allow you to
change values.
Once a value has been changed pressing > before
exiting the Menu will save the new setting. (The
figure shows Option 02 OFF).
04 Low Set Point C 5 High
Limit
5
Option 02 - Freeze Protection
Freeze protection will switch on the heating if the room
temperature falls to 5°C and will then control the
temperature at 7°C even if the Digistat is in OFF mode.
The Freeze Protection default is ON.
To switch off the Freeze Protection mode enter the
Installer Options Menu (Refer to Installer Options 02)
and change to OFF. Press > to accept.
Option 04 & 05 - Low and High Limit set points.
The user temperature set points defaults are High
32°C and Low 5°C, to change these limits enter the
Installer Options Menu (Refer to Installer Options 04
& 05).
Option 06 - Intelligent Delayed Start
(Energy saving feature).
The Intelligent Delayed Start is an energy saving
feature which automatically reduces the warm up time
for the heating system.
If enabled, the start time should be set an hour
earlier than the time you want the property to reach
the set temperature.
Intelligent Start will delay that start time, by an
amount that it has calculated based on the actual and
set temperature.
As the weather becomes milder, the start time is
delayed, so that fuel is not wasted bringing the room
up to temperature earlier than necessary.
DIGISTAT
INSTALLER OPTIONS
Installer
Options
Function Select
Option
Default
05 High Set Point C Low
Limit
32 32
Installer
Options
Function Select
Option
Default
06 Delayed Start (Energy
saving feature
On Off Off