Pre-Installation
19
Greenstar 4000 – 6 720 891 161 (2020/09)
4.4 Flue systems considerations
WARNING
Flue systems
Possible flue gas escape
Use Worcester, Bosch Group approved Condensfit II flue systems
only, no other manufacturer’s flue have been tested or approved for
use with Worcester, Bosch Group appliances.
CAUTION
Concealed flue systems:
Where a flue system is going to be concealed, provision must be
made for service and inspection.
Voids containing concealed flues must have at least one inspection
hatch no less than 300mm square.
Flue joints within the void must not be more than 1.5 metres from the
edge of the inspection hatch.
Inspection hatches should be located at changes of direction.
If this is not possible, bends should be viewable from both directions.
Refer to the manual supplied with the Worcester, Bosch Group flue kit for
complete installation instructions.
Flue kit part numbers
Table 12 Flue kit assembly part numbers
4.4.1 Flue length
Maximum horizontal flue lengths
Table 13 Maximum flue lengths - Horizontal flues
Maximum vertical flue lengths
Table 14 Maximum flue lengths - Vertical flues
Flue system bends
NOTICE
Effective flue lengths of bends:
Each bend used has an equivalent straight flue length.
Refer to table 15.
Table 15 Effective length of bends
NOTICE
Effective flue length of SimpleSwitch flue adaptor:
The SimpleSwitch flue adaptor has an equivalent straight flue length.
Refer to table 16.
Table 16 Effective length of SimpleSwitch flue adaptor
4.4.2 Flue options
The systems have different maximum flue lengths, refer to the following
example flue options for those maximum flue lengths.
Horizontal high level flue assembly
Fig. 14 Horizontal flue option
Flue length [L] (initial bend included in length calculation)
60/100 = 202 - 603mm
80/125 = N/A
Part number Flue Ø Description
7 733 601 245 60/100 4000 SimpleSwitch flue adaptor 60/100
7 716 191 082 60/100 Telescopic horizontal flue kit
7 716 191 171 60/100 Extended telescopic horizontal flue kit
7 733 600 048 60/100 Horizontal high level telescopic flue kit
7 719 003 702 80/125 Telescopic horizontal flue kit
7 719 002 430 60/100 Vertical balanced flue kit
7 719 002 431 80/125 Vertical balanced flue kit
7 733 600 298 60/100 1050mm horizontal fixed flue kit
Flue length [L] Flue length [L]
Appliance 60/100 80/125
GR4700iW 30 C 12,000mm 21,000mm
GR4700iW 25 C 12,000mm 21,000mm
Flue length [L] Flue length [L]
Appliance 60/100 80/125
GR4700iW 30 C 12,000mm 21,000mm
GR4700iW 25 C 12,000mm 21,000mm
Effective flue length
Bend 60/100 80/125
45° 0.5m 0.5m
90° 1.5m 1.5m
Effective flue length
60/100 80/125
4m N/A
0010015190-001
383 mm - 603 mm
60/100 mm
130 mm Min

Table of Contents

Other manuals for Worcester GR4700iW C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GR4700iW C and is the answer not in the manual?

Worcester GR4700iW C Specifications

General IconGeneral
BrandWorcester
ModelGR4700iW C
CategoryBoiler
LanguageEnglish

Related product manuals