Technical Specifications/Logs
85
Greenstar 4000 – 6 720 891 161 (2020/09)
Table 34 Technical data Greenstar 4000
Gas group classification (gas type) UK/IE CATII
2H/3P
Installation type C
13
, C
33
, C
53
General data
Expansion vessel capacity l 6 6
Expansion vessel pre-charge pressure bar 0.75 0.75
Appliance protection rating IP X4D X4D
Permissible ambient temperature °C 0-50 0-50
Nominal capacity of the appliance l 3.9 3.9
Total packaged weight kg 41.4 41.1
Total appliance weight (excluding packaging) kg 34.9 34.6
Lift weight (front panel removed) kg 32.3 32.0
Lift weight (front panel and expansion vessel removed) kg 28.4 28.1
SEDBUK 2009/12 % 90.4 90.4
SEDBUK 2005 % 91.8 91.8
1) For minimum and maximum permissable pressure refer to “Gas pressure within the system”, section 6.5.
2) Propane/butane mixture for fixed containers with capacity up to 15 000 litres.
3) Appliances are fitted with a flow regulator set to achieve a 40°C temperature rise. This ensures comfortable bathing during the colder winter months.
Greenstar 4000 GR4700iW 30 C LPG GR4700iW 25 C LPG
Description Unit

Table of Contents

Other manuals for Worcester GR4700iW C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GR4700iW C and is the answer not in the manual?

Worcester GR4700iW C Specifications

General IconGeneral
BrandWorcester
ModelGR4700iW C
CategoryBoiler
LanguageEnglish

Related product manuals