Table 4 Required AC wire size vs. required breaker rating
Required Breaker Size (amps) Required Wire Size
Freedom X (both
m
odels)
30 A maximum
20 A maximum through a GFCI
10 AWG
975-0787-01-01 21
Basic Installation Procedures
This section for use by qualified personnel only.
The AC input terminal is located inside the unit through the front
panel’s knockout hole and is labeled properly as AC IN or AC
INPUT. The unit comes with spring clamp-type terminals where
individual wires can be attached securely.
When making the AC input and AC output connections, observe the
correct color code for the appropriate
AC wire, as described below
in Table 5.
Table 5 Color codes for typical AC wiring
Color AC Wire
Black/Red Line
White/blue Neutral
Green/yellow or bare copper Ground (Earth)
Wiring Knockouts When installing wires to AC terminals,
always remove the appropriate wiring knockouts (there are two on
the AC panel) and install the proper strain-relief clamps or
bushings.
NOTICE
EQUIPMENT DAMAGE
Make sure the wires are connected properly. The AC wiring terminal
blocks are split into input and output sections.
Failure to follow these instructions can damage the unit and/or equipment.
NOTICE
REVERSE POLARITY DAMAGE
Make sure the wires are connected properly. Improper connections
(connecting a line conductor to a neutral conductor, for example) will
cause the Freedom X to malfunction and may permanently damage the
inverter. Damage caused by a reverse polarity connection is not covered
by your warranty.
Failure to follow these instructions can damage the unit and/or equipment.
Table 5 Color codes for typical AC wiring
Color AC Wire