Basic Installation Procedures
This section for use by qualified personnel only.
8. Using a 3mm slot long neck screwdriver, open the spring clamp
by inserting the tool in the clamp slot and gently pulling the
screwdriver handle forward, for Line terminal.
9. Insert Line AC wire into Line (L) terminal slot on the unit.
10. Release the spring clamp to secure the wire.
11. Repeat previous steps 8 through 10 for Ground (G) and
Neutral
(N) connections.
12. Tighten the strain relief clamp to secure the wires.
13. Replace the AC compartment cover onto the unit, if you are not
connecting other wires such as for the AC Output. Otherwise,
keep the AC compartment open and proceed to the next step.
14. Connect the other end of the wires to the circuit breaker in the
AC distribution panel supplying AC power to the unit.