Configuration
312 975-0125-02-01
Power Share
Configurable setting Power Share is a configurable setting that you set to match to the breaker rating on
the AC input. This setting is used to ensure that the charger limits its output to try
to prevent nuisance tripping of the AC input breaker due to the total current drawn
by the charger and your other AC loads. See also Power Share on page 222.
When to use Set the Power Share setting to match the AC input breaker. Use this setting when
connecting to an AC source. If using multiple AC sources via an AC transfer
switch, adjust this setting to the smaller AC breaker size.
Outcome Setting the value higher than the AC sources external breaker could cause the
external breaker to trip.
Equalize
Configurable setting This setting lets you enable or disable charger equalization, only if the battery type
is flooded (or wet).
Equalization can be turned on (enabled) or off (disabled).
When to use Review the section, Operating in Equalization Mode on page 218 before
adjusting this setting. This menu item is displayed if the battery type allows
equalization.
Power Share [10A]
Range of values Increment Default
5 to 50 amps 5 amp increments 30 amps
Equalize [Off]
Value Default
On
Off Off