Configuration
322 975-0125-02-01
Sub-Menus
Configure Inv/Chg Menu (Configure Inverter/Charger Menu)
Cfg/Inv Chg is a sub-menu. If selected, a list of sub-menu items appears.
Lo DC Volt
Full name Low DC input voltage shutdown
Configurable setting This setting lets you set the low voltage shutdown level for the inverter.
When to use This setting limits the depth of discharge on your house battery bank.
Batt Type
See a description of this feature on page 315.
Batt Size
See a description of this feature on page 315.
Sense Below
Configurable setting This setting lets you set the threshold for load sense power. This setting saves
battery consumption by keeping the inverter disabled (turned off) except when
load demand is present.
When to use Adjust this setting to control the inverter based on the load.
Outcome Sets the load threshold at a power level where you want the inverter to stay on, for
example, when a sufficient load is applied.
Lo DC Volt [10.0V]
Range Increment Default
10 to 13 volts 0.1 volt 10 volts
Sense Below [50W]
Range of values Increment Default
40 watts to 150 watts 10 watts 50 watts