Loading...
Sign Indicator and
Button
Description
iBMC direct
connect
management
port indicator
Indicates the status when the iBMC direct
connect management port connects to a
terminal (local PC):
Off: No terminal is connected.
Blinking green at short intervals for 3 seconds
and then off: The port is disabled.
Steady green: The terminal is connected.
Indicates the status when the iBMC direct
connect management port connects to a USB
device:
Blinking red at long intervals: The job fails or
an error is reported when the job is complete.
Blinking green at short intervals: The job is
being executed.
Blinking green at short intervals for 3 seconds
and then off: The port is disabled.
Steady green: The server configuration file is
being copied from the USB device or the job
is successfully completed.
5.1.3 Ports
Port Positions
4 x 3.5" drive configuration
Figure 5-7 Ports on the front panel
1
iBMC direct connect
management port
2 USB 3.0 port
3 USB 3.0 port 4 VGA port
8 x 2.5" drive configuration
FusionServer 1288H V7 Server
Technical White Paper 5 Hardware Description
Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd. 14