Activity
Indicator
(Green)
Fault Indicator
(Red/Blue)
Description
Steady on/
blinking
Blinking blue at 4
Hz
The NVMe drive is being located.
Blinking at 1 Hz Blinking red at 1
Hz synchronously
Data on the NVMe secondary drive is
being rebuilt.
Steady on/Off Red steady on The NVMe drive is faulty.
If the VMD function is disabled, the NVMe drives support only orderly hot swap.
Table 5-21 NVMe drive indicator description (VMD function disabled)
Activity
Indicator
(Green)
Fault Indicator
(Red/Blue)
Description
Off Off The NVMe drive is not detected.
Steady on Off The NVMe drive is detected and
operating properly.
Blinking at 4 Hz Off Data is being read from or written to
the NVMe drive.
Steady on/
blinking
Blinking blue at 4
Hz
The NVMe drive is being located.
Off Blinking red at
0.5 Hz
The NVMe drive has completed the
hot swap process and is removable.
Off Blinking red at 2
Hz
The NVMe drive is being hot-
swapped.
Steady on/Off Red steady on The NVMe drive is faulty.
5.5.3 RAID Controller Card
The RAID controller card supports RAID configuration, RAID level migration, and
drive roaming.
For details about the optional components, consult the local sales representative
or see "OS and Parts Compatibility" in the Compatibility Checker.
For details about the RAID controller card, see the V7 Server RAID Controller
Card User Guide.