5.4.1.6 Memory Protection Technologies
DDR5 memory modules support the following memory protection technologies:
ECC
Memory Mirroring
Memory Single Device Data Correction (SDDC)
Failed DIMM Isolation
Memory Thermal Throttling
Command/Address Parity Check and Retry
Memory Demand/Patrol Scrubbing
Memory Data Scrambling
Post Package Repair (PPR)
Write Data CRC Protection
Adaptive Data Correction - Single Region (ADC-SR)
Adaptive Double Device Data Correction - Multiple Region (ADDDC-MR)
Partial Cache Line Sparing (PCLS, HBM only)
5.5 Storage
5.5.1 Drive Configuration and Drive Numbering
5.5.1.1 4 x 3.5" Drive Pass-Through Configuration
Drive Configuration
Table 5-7 Drive configuration
Configuration
Front Drive Rear Drive Drive
Management
Mode
4 x 3.5" drive
pass-through
configuration 1
Front drives (4
x 3.5"):
Slots 0 to 3
support only
SATA drives.
- PCH
4 x 3.5" drive
pass-through
configuration 2
Front drives (4
x 3.5"):
Slots 0 to 3
support only
SAS/SATA
drives.
-
1 x PCIe RAID
controller card
The PCIe RAID
controller card
is installed in
slot 1 by
default.
FusionServer 1288H V7 Server
Technical White Paper 5 Hardware Description
Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd. 29