Unconnected  encoder 
cable or poor contact 
Check  whether  the  value  of 
U0-54 increases rapidly. If    yes, 
the  encoder  circuit  is 
disconnected.Disconnect  the 
power supply of the driver, check 
the  connection  of  the  encoder 
cable, if there is cable loosening, 
it  is  recommended  to  use  the 
multimeter to test the conduction 
condition;  after  eliminating 
errors, power on again 
Hot  plugging  is  strictly 
prohibited, and special cables are 
required for tank chains. 
Received  encoder  data 
errors,  and  the  number 
of  errors  exceeds  the 
number  of  error  retries 
of  encoder  registers 
P0-56 
Check whether the value of 
U0-79 and U0-54 increase. If yes, 
the encoder is interfered. Encoder 
wire and strong power do not 
have the same pipeline wiring; 
install filter on servo driver power 
input side; encoder wire sleeves 
magnetic ring; shut down welding 
machine type of equipment with 
large interference 
Too  many  CRC 
errors  in  encoder 
communication 
The  received  encoder 
data  is  wrong  and  the 
number  of  errors 
exceeds  the  value  in 
encoder  error  retry 
number register P0-56 
Encoder  interfered,  isolate 
interference source 
Absolute  value 
servo  encoder 
battery  low 
voltage  alarm 
(can  shield  this 
alarm) 
Battery  Voltage  in 
Battery Box of Encoder 
cable is less than 2.75V 
Please  replace  the  battery  while 
keeping the power supply ON of 
the servo driver in order to avoid 
the  error  of  encoder  position 
information.  Battery 
specification:  No.5  battery,  3.6V 
(model  CP-B-BATT, 
CPT-B-BATT) 
Power on alarm for new 
machine 
(1)  When  the  absolute  value 
motor is powered off, the memory 
position  depends  on  the  battery 
on  the  encoder  cable.  Once  the 
encoder  cable  and  the motor  are 
disconnected,  the  power  supply 
can not be carried out, which will 
lead  to  the  loss  of  the  current 
position  of  the  motor,  it  will 
alarm  222.    Please  set  F0-00=1 
to clear the alarm, it can be used 
normally. 
(2) The alarm can be shielded by 
using F0-79. When P0-79 is set to 
1, it will be used as a single-loop 
absolute  value  motor,  and  the 
current  position  will  not  be 
remembered when power off. 
Data access alarm 
of  absolute  value 
servo encoder 
Encoder  cable  with 
battery box  is not  used 
for  multi-turn  absolute 
motor 
①  Please use encoder cable with 
battery box; 
②  Power off and power on again