V5 series inverter
32
Fig.
Fig.
Fig.
Fig. 3
3
3
3 4
4
4
4 Display
Display
Display
Display during
during
during
during initialize,
initialize,
initialize,
initialize, STOP
STOP
STOP
STOP and
and
and
and RUN
RUN
RUN
RUN
2
2
2
2
.
.
.
.
Parameters
Parameters
Parameters
Parameters displayed
displayed
displayed
displayed in
in
in
in running
running
running
running status
status
status
status
When the inverter receive the running command, it starts to enter running status and operation panel will display running
monitor parameters, the default parameter is output frequency ( b-00 monitor parameter),as shown in Fig.3-4-B, the unit
indicator on the top right indicates the unit of this parameter
Press key can display parameter in running status circularly (defined
by
function code P3.41 and P3.42).While
displaying, press jkjk key to shift to the default parameter b-00 that is output frequency Otherwise, the operation panel
will display the last monitor parameter constantly.
3
3
3
3
.
.
.
.
Alarm
Alarm
Alarm
Alarm information
information
information
information
When then inverter detects a fault signal, the panel will display fault code, the code will flash to catch your attention as
shown in Fig.3-5; Press key to view the relative fault parameters in stopping status, and then press to shift to
fault code display.
If you want to view fault information, press to view P6 parameter in editing status.After you finding out and solve
the default, the inverter can be reset
by
key in operation panel or control terminals or communication command. The
fault code will not disappear until the fault is cleared .
Note
Note
Note
Note For some serious default such as over current, over voltage etc. please do not reset the inverter to rerun before
confirming that the default is cleared, otherwise the inverter may be damaged.
Fig.
Fig.
Fig.
Fig. 3
3
3
3 5
5
5
5 Alarming
Alarming
Alarming
Alarming display
display
display
display status
status
status
status
4
4
4
4
.
.
.
.
Editing
Editing
Editing
Editing status
status
status
status
This status can be entered
by
pressing key in stopping ,running or fault alarming status(if there is a user
s password,
you should input correct password, refer to P0.00 and Fig 3-9 for details).This status can be displayed in three level menu,
they a re: code gruop code No. code parameter, you can enter the sub-menu
by
pressing .In code parameter status,
press to save parameter and press to exit without saving.
Fig.
A
Fig. B
Fig. C
Power on and
initialize, display
the dynamic picture
S top status, display
the stop parameters
running status,
display the running
parameters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje VB5-41P5 and is the answer not in the manual?

Xinje VB5-41P5 Specifications

General IconGeneral
BrandXinje
ModelVB5-41P5
CategoryDC Drives
LanguageEnglish

Related product manuals