V5 series inverter
51
12
12
12
12 .
.
.
. Specail
Specail
Specail
Specail Application
Application
Application
Application function
function
function
function parameters
parameters
parameters
parameters (Group
(Group
(Group
(Group PB
PB
PB
PB )
)
)
)
13
13
13
13
.
.
.
.
Factory
Factory
Factory
Factory setting
setting
setting
setting (Group
(Group
(Group
(Group PF
PF
PF
PF )
)
)
)
PA.09
Stator resistance of motor
0.001 50.000 Ω
0.001 Ω
Dependent on
inverter
s model
×
PA.10
Rotor resistance of motor
0.001 50.000 Ω
0.001 Ω
Dependent on
inverter
s model
×
PA.11
Over current protection
coeff icient of torque
0 15
1
15
×
PA.12
Percentage adjustment
coefficient of speed deviation
50 120
1
85
×
PA.13
Integral adjustment coefficient
of speed deviation
100 500
1
360
×
PA.14
V
ector torque boost
100 150
1
80
×
PA.15
Reversed
0
0
0
×
PA.16
Reversed
1 5
1
4
×
PA.17
Reversed ( excitation)
100 150
1
100
×
PA.18
Reversed
150
1
150
×
PA.19
Reversed
0 2
1
0
Group
Group
Group
Group PB
PB
PB
PB Specail
Specail
Specail
Specail Application
Application
Application
Application function
function
function
function parameters
parameters
parameters
parameters
Parameter
Parameter
Parameter
Parameter
Name
Name
Name
Name
Range
Range
Range
Range
Minmum
Minmum
Minmum
Minmum unit
unit
unit
unit
Factory
Factory
Factory
Factory
setting
setting
setting
setting
Change
Change
Change
Change
PB.00
Jog frequency source
0 4
0 P3.06
1 Panel poten t iometer
2 P0.02
3 VI
4 CI
0
0
PB.01
selecti on of f orward/
r everse dead time
0 1
0 Dead time is enabled ( Min 0.1S)
1 dead time can be set to
0 P0.05=0.0S P0.20 0.5Hz is
needed
1
0
PB.02
I nverter type select
0: G type(normal)
1: P type( wind machine,water pump,
power increase s 1 level )
N ote: set as 1, P0.22 must set to 3.
1
0
×
PB.03
S hort the run point
before power on, set the
run m ode
0: after inverter is power on, run
immediately
1: after inverter is power on, cut off
the point and connect again to run
1
1
×
Group
Group
Group
Group PP
PP
PP
PP Factory
Factory
Factory
Factory Setting
Setting
Setting
Setting
Parameter
Parameter
Parameter
Parameter
Name
Name
Name
Name
Range
Range
Range
Range
Minmum
Minmum
Minmum
Minmum
unit
unit
unit
unit
Factory
Factory
Factory
Factory setting
setting
setting
setting
Change
Change
Change
Change
PF.00
Default password
-
-
-
*
PF.01
User
s password
0 With no password protection
0001 9999 passwor protection
1
0000