54
4-2.
4-2.
4-2.
4-2. Parameter
Parameter
Parameter
Parameter d
d
d
d escription
escription
escription
escription
4-2-1
4-2-1
4-2-1
4-2-1
.
.
.
.
Basic
Basic
Basic
Basic operating
operating
operating
operating function
function
function
function parameters
parameters
parameters
parameters ( Group
Group
Group
Group P0
P0
P0
P0 )
0
0
0
0 : V/F
V/F
V/F
V/F control
control
control
control
1
1
1
1 : Open
Open
Open
Open loop
loop
loop
loop vector
vector
vector
vector control
control
control
control
0
0
0
0 : Panel
Panel
Panel
Panel analog
analog
analog
analog potentiometer
potentiometer
potentiometer
potentiometer setting
setting
setting
setting
1
1
1
1 : and
and
and
and keys
keys
keys
keys on
on
on
on the
the
the
the panel
panel
panel
panel
Y
ou can set the reference frequency via and keys on the panel .
2
2
2
2 : Keyboard
Keyboard
Keyboard
Keyboard digital
digital
digital
digital
Initial frequency is the value of P0.02, to set the reference frequency via keyboard
by
modify ing the value of P0.02.
3
3
3
3 : Terminal
Terminal
Terminal
Terminal UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN
Initial frequency is the value of P0.02, to set the frequency via terminal UP/DOWN
.
4
4
4
4 : Serial
Serial
Serial
Serial port
port
port
port (
(
(
( remote
remote
remote
remote control
control
control
control )
)
)
)
Initial frequency
is
the value
of
P0.02,
to
set the frequency
via
serial
port .
5
5
5
5 : VI
VI
VI
VI a
a
a
a nalog
nalog
nalog
nalog input
input
input
input (VI
(VI
(VI
(VI - GND)
GND)
GND)
GND)
The reference frequency is set
by
analog voltage input via terminal VI, the input voltage range is DC 0~10V
.
The
corresponding relationship between frequency and VI is decided
by
parameters P1.00~P1.05.
6
6
6
6 : CI
CI
CI
CI analog
analog
analog
analog input
input
input
input (CI
(CI
(CI
(CI - GND)
GND)
GND)
GND)
The reference requency is set
by
analog voltage/current of terminal CI and the input range is DC: 0~10V ( if jumper JP3 is
placed on “ V ” side )
,
DC:4~20mA ( if jumper JP3 is placed on “ A ” side
)
.
Then corresponding relationship between
frequency and CI input is decided
by
parameter P1.06~P1.10 .
7
7
7
7 : Pulse
Pulse
Pulse
Pulse input
input
input
input (PLUSE)
(PLUSE)
(PLUSE)
(PLUSE)
The referency frequency is set
by
pulse input via pulse terminal ( can only be input via terminal X6
)
.
The corresponding
relationship between frequency and PLUSE input is decided
by
parameters P1.11~P1.15 .
8
8
8
8 : Combination
Combination
Combination
Combination
Please refer to P3.00 , to set the reference frequency via combination of channels .
When the reference frequency is set in digital
mode
( P0.01 = 1 ,
2
, 3 , 4
)
,
The setting of P0.02 is the inverter
’
s initial frequenc
y
value.
0
0
0
0 : Panel
Panel
Panel
Panel control
control
control
control
Input operating commands via panel start or stop the inverter
by
pressing
,
and on the panel.
1
1
1
1 : Terminal
Terminal
Terminal
Terminal control
control
control
control
Input operating commands via external s such as FWD,
REV,
X1~X6 to start or stop the inverter.
2
2
2
2 : Serial
Serial
Serial
Serial port
port
port
port control
control
control
control
To
start or stop the inverter via RS485 port.
Note
Note
Note
Note : The control modes can be control l ed
by
modifying P0. 03, while please be careful to use this method during
operating.