V5 series inverter
48
9
9
9
9
.
.
.
.
Simple
Simple
Simple
Simple PLC
PLC
PLC
PLC operation
operation
operation
operation parameters
parameters
parameters
parameters (
(
(
( Group
Group
Group
Group P8
P8
P8
P8 )
)
)
)
2 Analog reference by CI
P7.02
Feedback channel selection
0 VI (0~10V)
1 Analog reference by CI
2 VI+CI
3 VI-CI
4 Min VI CI
5 Max VI CI
1
1
P7.03
Reference filter
0.01 50.00s
0.01s
0.50s
P7.04
Feedback f ilter
0.01 50.00s
0.01s
0.50s
P7.05
S et reference in digital mode
0.00 10.00V
0.01V
0.00V
P7.06
Mi n reference
0.0 Max reference P7.08
0.1
0.0
P7.07
Feedback value corresponding
to min reference
0.0 100.0%
0.1
0.0
P7.08
Max reference
Min reference P7.06 100.0
0.1
100.0
P7.09
Feedback va lue corresponding
to max reference
0.0 100.0
0.1
100.0
P7.10
Proportional KP
0.000 9.999
0.001
0.050
P7.11
Integral KI
0.001 9.999
0.001
0.050
P7.12
Sampling cycle T
0.01 10.00S
0.01
1.00
P7.13
Limits of deviation
0.0 20.0
1
2.0
P7.14
Close loop adjustment
characteristic
0: Forward
1: Reverse
Note : relationship between reference temperature and
speed
1
0
×
P7.15
Integral adjustment selection
0 Stop integral adjustment selection when the
frequency reaches upper limit or lower limit s
1
Continue the integral adjustment selection when th e
frequency reaches hig h limit or lower limit s
1
0
×
P7.16
Close loop preset frequency
0 upper limit of of frequency
0.01Hz
0.00Hz
P7.17
Holding time of close loop
0.0 250.0s
0.1s
0.1s
×
P7.18
Threhold of zero-frequency
operation
0.00 500.00Hz
0.01Hz
0.01Hz
×
P7.19
Hysteresis of zero-frequency
operation
0.00 500.00Hz
0.01Hz
0.01Hz
×
Group
Group
Group
Group P8
P8
P8
P8 Simple
Simple
Simple
Simple PLC
PLC
PLC
PLC operation
operation
operation
operation parameters
parameters
parameters
parameters
Parameters
Parameters
Parameters
Parameters
Name
Name
Name
Name
Range
Range
Range
Range
Minmum
Minmum
Minmum
Minmum
unit
unit
unit
unit
Factory
Factory
Factory
Factory
setting
setting
setting
setting
Change
Change
Change
Change
P8.00
Simple PLC operation
mode selection
0000 1113
Unit
s place : mode selection
0 Disabled
1 Stop after single cycle of operation
2 Holding at the final value after sing le cycle of
operation
3 Operate continuously
Ten
s place :
PLC restarting mode after stopping
1
0000
×