Parameter initial ization
locking up
Unit
’
s place :
0: A ll parameters are allowed
modifying
1: Only P3.01 can be modified
2: Only P0.02 and P3.01 can be
modified
Ten
’
s place :
0 : disable d
1 : Res tore to factory setting
2 : Clear fault record
0: disabled
1: parameter upload
2: parameter download
Note : Function is still in developing
Auto energy-saving
function
0 : disabled
1 : enable all the time
2 : Disabled in Dec process
Acc time of jog operation
Dec time of jog operation
LED unit
’
s place : baud rate selection
0 : 1200BPS
1 : 2400BPS
2 : 4800BPS
3 : 9600BPS
4 : 19200BPS
5 : 38400BPS
LED ten
’
s place : data format
0 : 1 - 7 - 2 foramt , no parity check
1 : 1 - 7 - 1 format , Odd
2 : 1 - 7 - 1 format , Even
3 : 1 - 8 - 2 format , None
4 : 1 - 8 - 1 format , Odd
5 : 1 - 8 - 1 format , Even
6 : 1 - 8 - 1 format , None
( When use Modbus-RTU
communication mode , please select
data mode 3 ~ 6 。 )
LED hundred
’
s place :
undefined
0 ~ 248
0 : broadcast address
248 : inverter as the host address
Delay for responding to c