VB5N series inverter
42
Group P8: Simple PLC operation parameters
Simple PLC operation
mode selection
Lowest bit: mode selection
0: Disabled
1: Stop after single cycle
2: keep the final value after single cycle
3: continuous cycle
Ten bit: PLC pause and restartup mode selection
0: Run again from stage 1
1: Continue running from the pause frequency
Hundred bit: save PLC parameter when power off
0: Not saving
1: Save the frequency when power off
Thousand bit: time unit of stage running
0: second
1: minute
Lowest bit: frequency setup
0: Multi I (i=1~7)
1: Frequency P0.01
Ten bit: Operating direction selection
0: Run forward
1: Run reverse
2: Decided by operating instructions
Hundred bit: Acc/Dec time selection
0: Acc/Dec time 1
1: Acc/Dec time 2
2: Acc/Dec time 3
3: Acc/Dec time 4
4: Acc/Dec time 5
5: Acc/Dec time 6
6: Acc/Dec time 7
Operating time of stage 1
Operating time of stage 2
Operating time of stage 3
Operating time of stage 4
Operating time of stage 5
Operating time of stage 6
Operating time of stage 7