VB5N series inverter
53
The relationship between CI and setting frequency:
The relationship between PULSE and setting frequency:
4-2-3. Starting and braking parameters (Group P2)
P2.00
Starting mode
Range: 0, 1, 2
0
0: Start from the starting frequency
Inverter starts at the starting frequency (P2.01) within the lasting time of starting frequency (P2.02).
1: Brake first and then start from the starting frequency
Brake with DC braking current (P2.03) within braking time (P2.04) and then start at starting frequency.
2: Track the speed then start
When P2.00=2, it is valid for repowering after instantaneous power off or restarting after external fault. As shown in
Fig.4-9.
Fmin
Fmax
Amax
Amin
Set frequency
Fmin
Fmax
Amax
Amin
Set frequency
(1) positive function
(2) negative function
A
A
APULSE setting Aminmin setting Fminfrequency of min setting
Amaxmax setting Fmaxfrequency of max setting
Fmin
Fmax
Amax
Amin
Set frequency
Fmin
Fmax
Amax
Amin
Set frequency
(1) positive function
(2) negative function
A
A
ACI set frequency Aminmin setting Fminfrequency of min setting
Amaxmax setting Fmaxmax frequency of max setting