readout device. The user receives the radio key by downloading it from a secure platform. The link to the platform will be sent to the authorised
user by email.
Caution! The radio key must be assigned to the radio address of the meter and stored in a secure place. The loss of the radio key or incorrect
assignment leads to the loss of readability.
12. Last meter reading
Cordonel is equipped with an NFC interface, which stores and can transmit the last meter reading before failure in the case of a meter without
display and radio communication.
NFC means Near Field Communication and is a function integrated in modern mobile phones and supported by Android operating systems.
The NFC aerial of the Cordonel is arranged in a loop around the display.
For correct readout, the readout device with the NFC sensor (usually on the back of mobile phones) must be placed on the display of the Cordonel
and the app started. Sensus recommends the app NFC ST 25.
Readable values are:
Meter number
Last saved meter reading
Volume unit
Time that data was last saved
13. Factory settings
Values Unit DN 40 DN 50 DN 65 DN 80 DN 100
Leakage duration Days 14
Leakage threshold value m³/h 0.25 0.375 0.625 0.875 1.25
Pipe burst duration Min. 5
Pipe burst threshold value m³/h 25 37.5 62.5 87.5 125
Leakage alarm Off
Pipe burst alarm Off
Battery alarm On
Negative flow alarm On
Storage period of alarms Days 29
Data logger period Min. 60
Data logger forward volume Off
Data logger time minimum flow rate Off
Data logger minimum flow rate On
Data logger time pipe burst Off
Data logger pipe burst Off
Data logger instantaneous flow rate¹ Off
Data logger time peak flow rate² Off
Data logger peak flow rate² Off
Data logger time maximum flow rate³ Off
Data logger maximum flow rate³ Off
Data logger minimum pressure Off
Data logger time minimum pressure Off
Data logger maximum pressure Off
Data logger time maximum pressure Off
Data logger minimum temperature Off
Data logger time minimum temperature Off
Data logger maximum temperature Off
Data logger time maximum temperature Off
Data logger current pressure Off
Data logger current temperature Off
Data logger extended alarms Off
Cordonel
Page 9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem Sensus Cordonel DN 40 and is the answer not in the manual?

Xylem Sensus Cordonel DN 40 Specifications

General IconGeneral
BrandXylem
ModelSensus Cordonel DN 40
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals