EasyManua.ls Logo

Yaesu FT-2000 - IF Noise Blanker (NB) Operation

Yaesu FT-2000
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 61FT-2000D OPERATING MANUAL
IF NOISE BLANKER
(
NB
)
OPERATION
The FT-2000D includes an effective IF Noise Blanker, which can significantly reduce noise caused by automotive ignition
systems.
Main band
(
VFO-A
)
NB Operation
1. Press the
[
NB
]
button momentarily to reduce short-
duration pulse noise such as from switching transients,
automobile ignitions and power lines. The “ ” icon
will appear in the display to confirm that the Narrow-
NB is operating. Press and hold in the
[
NB
]
button for
two seconds to reduce longer-duration man-made pulse
noise. The “ ” icon will blink for five seconds, and
thereafter will appear continuously, to confirm that the
Wide-NB is operating.
2. Advance the
[
NB
]
knob to the point where the offend-
ing noise is best reduced or eliminated.
3. To end Noise Blanker operation, press the
[
NB
]
but-
ton once more. The “ ” icon will turn off, confirm-
ing that the Noise Blanker is no longer in operation.
AD VICE:
When the Roofing filter mode is set to “AUTO” and
the Noise Blanker is turned On, the Roofing Filter band-
width will automatically be set to 15 kHz. The Roof-
ing Filter may be changed to a narrower selection, as
described previously, although Noise Blanker opera-
tion may be compromised somewhat when using a nar-
rower Roofing Filter.
When you change the Noise Blanker level on the Main
(VFO-A) side, the Sub (VFO-B) band’s Noise Blanker
level will automatically change to be the same as that
for VFO-A, if the Sub (VFO-B) band’s Noise Blanker
is engaged.
Main Band
(
VFO-A
)
NB” Icon
[
B
]
Button
Sub Band
(
VFO-B
)
NB” Icon
[
NB
]
Button
I
NTERFERENCE
R
EJECTION
(
S
IGNALS
WITHIN
3
KHZ
)
[
NB
]
Knob
Sub band
(
VFO-B
)
NB Operation
1. Press the
[
B
]
button.
2. Within five seconds of pressing the
[
B
]
button (while
the imbedded orange LED is blinking), press the
[
NB
]
button momentarily to reduce short-duration pulse
noise such as from switching transients, automobile ig-
nitions and power lines. The “ ” icon will appear in
the display to confirm that the Narrow-NB is operat-
ing.
3. Within five seconds of pressing the
[
B
]
button (while
the imbedded orange LED is blinking), press and hold
in the
[
NB
]
button for two seconds to reduce longer-
duration man-made pulse noise. The “ ” icon will
blink for five seconds, then appear continuously, to con-
firm that the Wide-NB is operating.
4. To end Noise Blanker operation, press the
[
B
]
button,
then press the
[
NB
]
button. The “ ” icon will turn
off, confirming that the Noise Blanker is no longer in
operation.
AD VICE:
When you change the Noise Blanker level on the Sub
(VFO-B) side, the Main (VFO-A) band’s Noise Blanker
level will automatically change to be the same as that for
VFO-B, if the Main (VFO-A) band’s Noise Blanker is
engaged.

Table of Contents

Other manuals for Yaesu FT-2000

Related product manuals