31
DG-Stomp
If an error occurs during operation, one of the following error message numbers will appear on the display.
E1: MIDI Receive Buffer Full
CAUSE: Too much MIDI data is being received by the DG amplifier at one time.
SOLUTION:Try reducing the amount of data being sent or, break the data into smaller blocks.
E2: Communication Error.
CAUSE: An abnormality is detected during MIDI communications.
SOLUTION:Check all connections, etc. and try again.
E3: Bulk Receive Check Sum Error.
CAUSE: The check sum does not match the received MIDI bulk data.
SOLUTION:Check all connections and data, and try again.
E4: Bulk Receive Data Abnormality.
CAUSE: An abnormality is detected in the received MIDI bulk data.
SOLUTION:Check all connections and data, and try again.
E5: Backup Battery Error.
CAUSE: Backup battery power is depleted.
SOLUTION:Continued use of the device will result in the loss of data. Return the device to the music
dealer where you purchased it or, have the battery replaced.
ERROR MESSAGES