EasyManua.ls Logo

Yanmar EF494T - Checking Fluid Lines; Checking Electrical Wiring

Yanmar EF494T
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EF494T OM
63
IMPORTANT
Be sure the tractor is level when checking electrolyte level.
When connecting the battery cables, wipe oil away
from the terminal contacts. After connecting cables,
apply grease to the terminals.
Be sure to attach the rubber boots for the positive
terminal of the battery.
When replacing the battery, be sure to use the genuine
battery or equivalent specified in the right table.
For environmental protection and recycle of
resources, return the old battery fallowing the
regulation of your place.
Battery type
Specified battery Parts code No.
75D26R 1A7781-51510
Voltage 12Volts
Capacity 5HR 52AH
Charging rate 11 Amperes
10. Checking fluid lines
CAUTION
Aged or damaged pipes are subject to fuel leak which
will cause a fire. Check for a leak and replace the pipe
with new one.
Check the power steering pipes, fuel pipes and radiator
hoses for leak or loose couplings. Replace them every
two years, damaged or not damaged.
(A) Radiator hose
(B) Fuel pipe
(C) Power steering pipes
NOTE:
Bleed the air after the fuel pipe has been replaced.
11. Checking electrical wiring
WARNING
Check before starting day's work that the cables are
not short circuit to other parts or insulator is not
damaged, or contacts are not loosened.
Remove straws and dust from the cables and joints
before starting works. Otherwise, a short circuit can
cause a fire.
Remove the engine side cover and check the
electrical wires for damaged sheaths or loose
connections. Repair them or consult your service
representative.
Check them every 50 hours or every year.

Table of Contents