5 Specifications
66 YASKAWA TOEPC71061779D GA800 Drive Installation Manual
Item Specification
Frequency Setting
Signal
Main speed frequency reference: -10 Vdc to +10 Vdc (20 kΩ), 0 Vdc to 10 Vdc (20 kΩ), 4 mA to 20 mA (250 Ω), 0 mA to 20 mA (250 Ω)
Main speed reference: Pulse train input (maximum 32 kHz)
Starting Torque
V/f: 150%/3 Hz
CL-V/f: 150%/3 Hz
OLV: 200%/0.3 Hz
CLV: 200%/0 min
-1
(r/min)
AOLV: 200%/0.3 Hz
OLV/PM: 100%/5% speed
AOLV/PM: 200%/0 min
-1
(r/min)
CLV/PM: 200%/0 min
-1
(r/min)
EZOLV: 100%/1% speed
Note:
Correctly select the drive and motor capacity for this starting torque in these control methods:
OLV
CLV
AOLV
AOLV/PM
CLV/PM
Set n8-57 = 1 [HFI Overlap Selection = Enabled] for this starting torque in AOLV/PM. When you use a non-Yaskawa PM motor, do Rotational Auto-
Tuning.
Speed Control Range
V/f: 1:40
CL-V/f: 1:40
OLV: 1:200
CLV: 1:1500
AOLV: 1:200
OLV/PM: 1:20
AOLV/PM: 1:100 (when high frequency injection is enabled)
CLV/PM: 1:1500
EZOLV: 1:100
Note:
Set n8-57 = 1 [HFI Overlap Selection = Enabled] for this Speed Control Range in AOLV/PM. When you use a non-Yaskawa PM motor, do Rotational
Auto-Tuning.
Speed control range of 1:100 for AOLV/PM is Instantaneous operation range. Correctly select the drive and motor capacity for continuous operation.
Zero Speed Control
Possible in these control methods:
CLV
AOLV/PM
CLV/PM
Torque Limits
Parameter settings allow different limits in four quadrants in these control methods:
OLV
CLV
AOLV
AOLV/PM
CLV/PM
EZOLV
Accel/Decel Time
0.0 s to 6000.0 s
The drive can set four pairs of different acceleration and deceleration times.
Braking Torque
Approximately 20%
Approximately 125% with a dynamic braking option
Short-time average deceleration torque
Motor output 0.4/0.75 kW: over 100%
Motor output 1.5 kW: over 50%
Motor output 2.2 kW and larger: over 20%, Overexcitation Braking/High Slip Braking allow for approximately 40%
Continuous regenerative torque: Approximately 20%. Dynamic braking option allows for approximately 125%, 10%ED, 10 s
WARNING
Set L3-04 = 0 [Stall Prevention during Decel = Disabled] when you operate the drive with:
a regenerative converter
regenerative unit
braking unit
braking resistor
braking resistor unit.
If you set the parameter incorrectly, the drive can decelerate for too long and cause serious injury or death.
Note:
Models 2004 to 2138 and 4002 to 4168 have a braking transistor.
Short-time average deceleration torque refers to the torque needed to decelerate the motor (uncoupled from the load) from the rated speed to zero. Motor
characteristics can change the actual specifications.
Motor characteristics change the continuous regenerative torque and short-time average deceleration torque for motors 2.2 kW and larger.