EasyManua.ls Logo

YASKAWA GPD 315/V7 - Page 31

YASKAWA GPD 315/V7
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GPD315/V7 Modbus RTU Technical Manual TM 4325
Page
27
Table 5-4 Drive Parameters (continued)
Parameter ADDR Name Set
Description
Default
n069 0145h
Analog
Frequency Ref.
Bias
±100% (Operator Voltage Input) 0
n070 0146h
Analog
Freq. Ref. Filter
Time Constant
0.00 To 2.00 Seconds (Operator Voltage Input)
0.00 = Filter Disabled
0.10
n071 0147h
Analog
Frequency Ref.
Gain
±255% (Operator Current Input) 100
n072 0148h
Analog
Frequency Ref.
Bias
±100% (Operator Current Input) 0%
n073 0149h
Analog
Freq. Ref. Filter
Time Constant
0.00 - 2.00 Seconds (Operator Current Input)
0.00 = Filter Disabled
0.10
n074 014Ah
Pulse String
Freq. Ref. Gain
±255% 100
n075 014Bh
Pulse String
Freq. Ref. Bias
±100% 0
n076 014Ch
Pulse String
Freq. Ref. Filter
Time Constant
0.00 - 2.00 Seconds
0.00 = Filter Disabled
0.10
0 Multi-Function Analog Input Disabled
1 Aux. Frequency Reference (FREF2)
2 Frequency Gain (FGAIN)
3 Frequency Bias (FBIAS)
n077
4
014Dh
Multi-Function
Analog Input
Selection
4 Output Voltage Bias (VBIAS)
0
0 0 10V (Operator Terminal)
n078
4
014Eh
Multi-Function
Analog Input
1 4 20ma (Operator Terminal)
0
n079
4
014Fh
Multi-Function
Analog
Frequency Bias
0 50% (100%/Max. Output Freq. (n011)) 10
1 To 4 Carrier Frequency = set value * 2.5kHz
n080 0150h
Carrier
Frequency
7 To 9 1 2.5kHz (Synchronous)
4
6
0 Operation Does Not Continue
1 Operation Continues within momentary power loss ride through
n081 0151h
Momentary
Power Loss
Selection
2 Continuous Operation (No UV1 Fault)
0
n082 0152h Fault Retries 0 - 10 Attempts 0
n083 0153h
Prohibit
Frequency 1
0.00 - 9.99hz or 100.0 - 400.0hz (0.000 Disables) 0.00
n084 0154h
Prohibit
Frequency 2
0.00 - 9.99hz or 100.0 - 400.0hz (0.000 Disables) 0.00
n085 0155h
Prohibit
Frequency 3
0.00 - 9.99hz or 100.0 - 400.0hz (0.000 Disables) 0.00
n086 0156h
Prohibit Freq.
Deadband
0.00 - 25.50hz (0.00 Disables N083-N085) 0.00
0 Operation Time Elapses When Power Is On.
n087 0157h
Elapsed Time
Function
1 Operation Time Elapses When Drive Is Running
0
n088 0158h
Elapsed Time
(Initial Value)
0 - 9999hr 0
n089 0159h
DC Injection
Current
0 100% (0% = Baseblock) 50

Table of Contents

Other manuals for YASKAWA GPD 315/V7