2.6 Communication Time-out Error
2-12
2.6 Communication Time-out Error
The communication with MPE720 is processed with a lower priority than the high-speed scan processes.
Because of this, the communication with MPE720 may time out if the high-speed scan time is set too small.
Set a large enough value for the high-speed scan compared to the current and maximum values during the
operation of the application.
The set value, current value, and maximum value of the high-speed scan can be checked and set in the
Environment Setting window of MPE720 version 6.
Environment Setting Window of MPE720 Version 6