Drive Model
Wire Gauge (AWG, kcmil)
Screw
Size
Crimp
Terminal
Model Number
Tool
Insulation Cap
Model No.
Code
<1>
R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 Machine No. Die Jaw
4A0072
4
M8
R22-8
YA-5
AD-953 TP-022 100-051-263
3 R38-8 AD-954 TP-038 100-051-264
4A0088
3
M8
R38-8
YA-5
AD-954 TP-038 100-051-2642
1
1/0 R60-8 AD-955 TP-060 100-051-265
4A0103
2
M8
R38-8
YA-5
AD-954 TP-038 100-051-264
1 1
1/0 1/0 R60-8 AD-955 TP-060 100-051-265
4A0139
1/0
M10
R60-10
YF-1
YET-300-1
TD-321,
TD-311
TP-060 100-051-266
2/0 2/0 70-10
TD-323,
TD-312
TP-080
100-054-036
3/0 3/0 80-10 100-051-267
4/0 R100-10
TD-324,
TD-312
TP-100 100-051-269
4A0165
3/0
M10
80-10
YF-1
YET-300-1
TD-323,
TD-312
TP-080 100-051-267
4/0 R100-10
TD-324,
TD-312
TP-100 100-051-269
4A0208
2 × 2P
M10
38-L10
YF-1
YET-150-1
TD-224,
TD-212
TP-038 100-051-556
1 × 2P
3/0 × 2P 80-L10
TD-227,
TD-214
TP-080 100-051-557
4/0 R100-10
TD-228,
TD-214
TP-100 100-051-269
250
R150-10
TD-229,
TD-215
TP-150 100-051-272
300
4A0250
1 × 2P
M10
38-L10
YF-1
YET-150-1
TD-224,
TD-212
TP-038 100-051-556
3/0 × 2P 80-L10
TD-227,
TD-214
TP-080 100-051-557
4/0 × 2P 100-L10
TD-228,
TD-214
TP-100 100-051-559
250 × 2P 150-L10
TD-229,
TD-215
TP-150 100-051-561
300 R150-10 TP-150 100-051-272
350 180-10
YF-1
YET-300-1
TD-327,
TD-314
TP-200
100-066-687
400 200-10 100-051-563
500
325-10
TD-328,
TD-315
TP-325 100-051-565
600
4A0296
3/0 × 2P
M12
80-L12
YF-1
YET-300-1
TD-323,
TD-312
TP-080 100-051-558
4/0 × 2P 100-L12
TD-324,
TD-312
TP-100 100-051-560
250 × 2P
150-L12
TD-325,
TD-313
TP-150 100-051-562
300 × 2P
350 × 2P 180-L12
TD-327,
TD-314
TP-200
100-066-688
350 180-12 100-066-689
400 R200-12 100-051-275
500
325-12
TD-328,
TD-315
TP-325 100-051-277
600
i.3 Electrical Installation Safety
YASKAWA ELECTRIC TOEP YAIP1U 03B YASKAWA AC Drive – P1000 Safety Precautions
33

Other manuals for YASKAWA P1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA P1000 and is the answer not in the manual?

YASKAWA P1000 Specifications

General IconGeneral
Operating Temperature-10°C to +50°C (14°F to 122°F)
Cooling MethodFan Cooled
Output Voltage0-Input Voltage
Output Frequency0-400 Hz
Frequency Range0.1-400 Hz
Power Rating0.4 kW to 630 kW
Control MethodV/f Control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit, Ground Fault
Protection FeaturesElectronic Thermal Overload Protection
CommunicationModbus RTU
Communication InterfaceRS-485
Humidity5% to 95% (non-condensing)
AltitudeUp to 1000m (3280ft) without derating
Enclosure RatingIP20