コンプリメンタリタイプPG
取扱説明書
形  式
PG-B3
Complementary Type PG
Installation Manual
Type: PG-B3
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.
製品を安全にお使いいただくために,この取扱説明書を必ずお読みください。
また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる
ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。
COSMOS(140×182)(和英併記)新CI
MANUAL NO. TOBP C730600 75B
YASKAWA AC Drive Option
安川インバータ オプション

Questions and Answers

  • J
    Jonathan PeckJul 31, 2025
    How to fix speed deviation on YASKAWA pg-b3?
    • C
      Christine HuffmanJul 31, 2025
      If the YASKAWA Controller experiences speed deviation in control mode with PG, consider the following: * If the load is too heavy, reduce it. * If acceleration and deceleration times are too short, increase them using parameters C1-01 through C1-08. * If the load is locked, check the machine. * If parameters are set inappropriately, check F1-10 and F1-11 settings. * Ensure the motor brake releases properly.
  • M
    Mrs. Sharon HeathAug 4, 2025
    What to do if YASKAWA pg-b3 Controller shows overspeed?
    • F
      Frank ChapmanAug 4, 2025
      If the YASKAWA Controller shows an overspeed error: * If overshoot occurs, increase the setting for C5-01 (Speed Control Proportional Gain 1) and reduce C5-02 (Speed Control Integral Time 1). Adjust the input signal using parameters H6-02 through H6-05. You can also enable Feed Forward Control and perform Inertia Auto-Tuning in CLV. * If the speed feedback scaling is incorrect when terminal RP is used as speed feedback input in V/f control, set H6-02 to the value of the speed feedback signal frequency when the motor runs at the maximum speed. * If parameter settings are inappropriate, check the setting for the overspeed detection level and the overspeed detection time (F1-08 and F1-09).
  • J
    James LawrenceAug 8, 2025
    How to resolve Z Channel Pulse Noise Fault Detection on YASKAWA pg-b3?
    • B
      Brian HuberAug 8, 2025
      If the YASKAWA Controller detects Z Channel Pulse Noise Fault: * Separate the PG encoder cable wiring from the source of the electrical interference (e.g., drive output wiring). * Make sure the PG encoder is properly wired or is not disconnected and all shielded lines are properly grounded. * Confirm that the PG encoder is properly connected and all shielded lines are properly grounded. Cycle power. Replace the PG option card or the PG encoder if the problem continues after cycling power.
  • M
    Michael RobinsonAug 13, 2025
    What to do if YASKAWA Controller shows PG Encoder Disconnected?
    • S
      scott66Aug 13, 2025
      If the YASKAWA Controller detects a PG Encoder disconnection: * Ensure the PG encoder is properly wired and not disconnected. * Confirm that the correct power supply is properly connected to the PG encoder. * Ensure the brake releases properly.
  • B
    Brian SantosAug 17, 2025
    How do I fix a Control Method Selection Error on my YASKAWA pg-b3?
    • M
      Michael WilliamsonAug 17, 2025
      If the YASKAWA Controller gives a 'Control Method Selection Error' message, it means the control method requires a PG option, but none is installed. To resolve this: * Connect a PG option. * Correct the value set to A1-02.
  • P
    Preston BallAug 21, 2025
    What to do if option connection error occurs at drive port CN5-B of YASKAWA Controller?
    • W
      warnersethAug 21, 2025
      If the option in drive port CN5-B was changed during run on the YASKAWA Controller, de-energize the drive and plug the option into the drive according to Installation Procedure on Page 11.
  • A
    anthonyrobertsonAug 26, 2025
    What to do if option connection error occurs at drive port CN5-C of YASKAWA Controller?
    • M
      mthompsonAug 26, 2025
      If the option at drive port CN5-C was changed during run on the YASKAWA Controller, de-energize the drive and plug the option into the drive according to Installation Procedure on Page 11.

Summary

Preface and Safety

Applicable Documentation

Lists related manuals for the option and drive.

Terms and Abbreviations

Defines technical terms and abbreviations used in the manual.

Supplemental Safety Information

Explains safety message conventions (DANGER, WARNING, CAUTION, NOTICE).

General Safety

Provides general safety precautions and warnings for installation and operation.

Product Overview

About This Product

Describes the function and purpose of the PG-B3 Option.

Applicable Models

Lists the Yaskawa drive models compatible with the PG-B3 Option.

Receiving

Option Package Contents

Details the items included in the PG-B3 option package.

Installation Tools

Lists the tools required for installing the option.

Option Components

PG-B3 Option

Identifies the main components of the PG-B3 option.

Terminal Blocks TB1 and TB2

Shows the layout and labels of terminal blocks TB1 and TB2.

Installation Procedure

Section Safety

Highlights critical safety precautions for the installation procedure.

Procedure A

Details installation steps for 1000-series drives.

Procedure B

Details installation steps for GA700, CR700, and CH700 drives.

Connection Diagram

Illustrates the wiring connections for the PG-B3 option.

Wire Gauges, Tightening Torques, and Crimp Terminals

Specifies wire gauge, torque, and crimp terminal requirements.

PG Encoder Cables

Recommends specific cables for connecting the PG encoder.

Terminal Functions

Explains the function of each terminal on the option.

Related Parameters

Table 10 Related Parameters

Lists drive parameters for setting up the PG-B3 option.

Troubleshooting

Drive-Side Error Codes

Lists fault codes related to the option and their causes/solutions.

Table 11 Fault Displays, Causes, and Possible Solutions

Details error codes, causes, and solutions for the PG option.

Table 12 Operation Error Displays, Causes, and Possible Solutions

Lists operation errors, their causes, and possible solutions.

Preventing Electrical Interference

Provides steps to prevent noise interference with PG signals.

Interface Circuit

Explains the complementary output interface circuit.

Open-Collector Outputs

Explains the open-collector output interface circuit.

European Standards

CE Mark

Explains the meaning and requirement of the CE mark.

EMC Guidelines Compliance

States compliance with European EMC guidelines and harmonized standards.

EMC Guidelines Installation Conditions

Lists installation conditions for EMC compliance.

Specifications

Table 13 Option Specifications

Details the technical specifications of the PG-B3 option.

Revision History

YASKAWA pg-b3 Specifications

General IconGeneral
BrandYASKAWA
Modelpg-b3
CategoryController
LanguageEnglish

Related product manuals