8 Communication Objects Overview
30 YAS K AWA E L E C T R I C TOBP C730600 24D 1000-Series Option SI-S3/V, SI-S3/T Installation Manual
Output
2100 Drive Status
2101
<1> Drive Status (Change of State filter support)
2110 Output Frequency
2111
<1> Output Frequency (Change of State filter support)
2120 Output Current
2121
<1> Output Current (Change of State filter support)
2130 Output Torque
2131
<1> Output Torque (Change of State filter support)
2140 MEMOBUS/Modbus Read Command Response
2150 MEMOBUS/Modbus Write Command Response
2155
<1> PDO Parameter Write Response
2160 MEMOBUS/Modbus Not Limited Enter Command Response
2180
<1> Freely selectable (default: Input terminal status)
2190
<1> Freely selectable (default: Analog input 1 monitor)
21A0
<1> Freely selectable (default: none)
21B0
<1> Freely selectable (default: none)
21C0
<1> Freely selectable (default: none)
21D0
<1> Freely selectable (default: none)
21E0
<1> Freely selectable (default: none)
21F0
<1> Freely selectable (default: none)
2200 Motor Speed
<2>
2201 <1> Motor Speed (Change of State filter support) <2>
<1> Available in option unit software version 3102 and later.
<2> Units for motor speed are determined by o1-03. If the control mode for the drive is set to V/f control (A1-02 = 0)
and V/f control with simple PG feedback is disabled (H6-01 3), then the motor speed will be 0.