EasyManuals Logo

YASKAWA Varispeed f7 User Manual

YASKAWA Varispeed f7
463 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #263 background imageLoading...
Page #263 background image
6-68
Related Constants
Con-
stant
Number
Name Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor
b3-01
Speed search
selection
(current
detection or
speed calcu-
lation)
Enables/disables the speed
search function for the Run
Command and sets the speed
search method.
0: Disabled, speed calculation
1: Enabled, speed calculation
2: Disabled, current detection
3: Enabled, current detection
Speed Calculation:
When the search is started, the
motor speed is calculated and
acceleration/deceleration is
performed from the calculated
speed to the specified
frequency (motor direction is
also searched).
Current Detection:
The speed search is started
from the frequency when
power was momentarily lost
and the maximum frequency,
and the speed is detected at the
search current level.
0 to 3
2
*1
No A A A No 191H
b3-02
Speed search
operating cur-
rent (current
detection)
Sets the speed search operation
current as a percentage, taking
the Inverter rated current as
100%.
Not usually necessary to set.
When restarting is not possible
with the factory settings, reduce
the value.
0 to
200
120%
*1
No A No A No 192H
b3-03
Speed search
deceleration
time (current
detection)
Sets the output frequency decel-
eration time during speed search
in 1-second units.
Set the time for deceleration
from the maximum output fre-
quency to the minimum output
frequency.
0.1 to
10.0
2.0 s No A No A No 193H
b3-05
Speed search
wait time
(current
detection or
speed calcu-
lation)
Sets the magnetic contactor
operating delay time when there
is a magnetic contactor on the
output side of the Inverter.
When a speed search is per-
formed after recovering from a
momentary power loss, the
search operation is delayed by
the time set here.
0.0 to
20.0
0.2 s No A A A A 195H
b3-10
Sets the mag-
netic flux
compensa-
tion as a per-
centage of the
no-load cur-
rent.
Operation restarts at a speed
obtained by multiplying the
speed from the speed search by
the compensation gain (excita-
tion search only.)
Increase this setting if overvolt-
ages occur when a speed search
is performed after a long base-
block, for example, in searches
at startup.
1.00 to
1.20
1.10 No A No A No 19AH

Table of Contents

Other manuals for YASKAWA Varispeed f7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed f7 and is the answer not in the manual?

YASKAWA Varispeed f7 Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed f7
CategoryInverter
LanguageEnglish

Related product manuals