Monitor Constants
This section explains the analog monitor and pulse monitor constants.
îš‹ Using the Analog Monitor Constants
This section explains the analog monitor constants.
Related Constants
Con-
stant
Number
Name Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor
H4-01
Monitor
selection (ter-
minal FM)
Sets the number of the monitor
item to be output (U1-)
from terminal FM. The monitor
items that can be set depends on
the control method.
4, 10 to 14, 25, 28 to 31, 34, 35,
39 to 43 cannot be set.
1 to 99 2 No A A A A 41DH
H4-02
Gain (termi-
nal FM)
Sets the multi-function analog
output 1 voltage level gain.
Sets whether the monitor item
output will be output in multi-
ples of 10 V.
The maximum output from the
terminal is 10 V.
A meter calibration function is
available.
0.00 to
2.50
1.00 Yes Q Q Q Q 41EH
H4-03
Bias (termi-
nal FM)
Sets the multi-function analog
output 1 voltage level bias.
Sets output characteristic up/
down parallel movement as a
percentage of 10 V.
The maximum output from the
terminal is 10 V.
A meter calibration function is
available.
-10.0 to
+10.0
0.0% Yes A A A A 41FH
H4-04
Monitor
selection (ter-
minal AM)
Sets the number of the monitor
item to be output (U1-)
from terminal AM.
The monitor items that can be
set depends on the control
method.
4, 10 to 14, 25, 28 to 31, 34, 35,
39 to 43 cannot be set.
1 to 99 3 No A A A A 420H
H4-05
Gain (termi-
nal AM)
Set the voltage level gain for
multi-function analog output 2.
Set the number of multiples of
10 V to be output as the 100%
output for the monitor items.
The maximum output from the
terminal is 10 V.
A meter calibration function is
available.
0.00 to
2.50
0.50 Yes Q Q Q Q 421H

Table of Contents

Other manuals for YASKAWA Varispeed f7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed f7 and is the answer not in the manual?

YASKAWA Varispeed f7 Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed f7
CategoryInverter
LanguageEnglish

Related product manuals