5-26
Reference Constants: d
The following settings are made with the reference constants (d constants): Frequency references.
Preset Reference: d1
User constants for frequency references are shown in the following table.
Con-
stant
Number
Name Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor
d1-01
Frequency
reference 1
Sets the frequency reference
in the units used in o1-03.
0.00 to
400.00
*1 *3
0.00
Hz
Yes Q Q Q Q 280H
4-6
6-10
d1-02
Frequency
reference 2
The frequency reference
when multi-step speed refer-
ence 1 is ON for a multi-
function input.
0.00
Hz
Yes Q Q Q Q 281H
4-6
6-10
d1-03
Frequency
reference 3
The frequency reference
when multi-step speed refer-
ence 2 is ON for a multi-
function input.
0.00
Hz
Yes Q Q Q Q 282H
4-6
6-10
d1-04
Frequency
reference 4
The frequency reference
when multi-step speed refer-
ences 1 and 2 are ON for
multi-function inputs.
0.00
Hz
Yes Q Q Q Q 283H
4-6
6-10
d1-05
Frequency
reference 5
The frequency when multi-
step speed reference 3 is ON
for a multi-function input.
0.00
Hz
Yes A A A A 284H 6-10
0.00 to
300.00
*1 *2
d1-06
Frequency
reference 6
The frequency reference
when multi-step speed refer-
ences 1 and 3 are ON for
multi-function inputs.
0.00
Hz
Yes A A A A 285H 6-10
d1-07
Frequency
reference 7
The frequency reference
when multi-step speed refer-
ences 2 and 3 are ON for
multi-function inputs.
0.00
Hz
Yes A A A A 286H 6-10
d1-08
Frequency
reference 8
The frequency reference
when multi-step speed refer-
ences 1, 2, and 3 are ON for
multi-function inputs.
0.00
Hz
Yes A A A A 287H 6-10
d1-09
Frequency
reference 9
The frequency reference
when multi-step speed refer-
ence 4 is ON for a multi-
function input.
0.00
Hz
Yes A A A A 288H -
d1-10
Frequency
reference 10
The frequency reference
when multi-step speed refer-
ences 1 and 4 are ON for
multi-function inputs.
0.00
Hz
YesAAAA28BH-
d1-11
Frequency
reference 11
The frequency reference
when multi-step speed refer-
ences 2 and 4 are ON for a
multi-function inputs.
0.00
Hz
YesAAAA28CH-