Protective and Diagnostic Functions
7-17
Copy
ID not matched
The Inverter product code or software
number is different.
Use the copy function for the same
product code and software number.
Inverter capacity
matched
The capacity of the Inverter being
copied and the capacity in the Digital
Operator are different.
Use the copy function for the same
Inverter capacity.
Control method
matched
The control method of the Inverter
being copied and the control method
in the Digital Operator are different.
Use the copy function for the same
control method.
Verify error
The constant written to the Inverter
was compared with the constant in the
Digital Operator and they were differ-
ent.
Retry the copy.
Checksum error
The checksum in the Inverter constant
area was compared with the checksum
in the Digital Operator constant area
and they were different.
Retry the copy.
Verify
Verify error
The Digital Operator and Inverter set-
tings do not agree.
Retry the copy and verify again.
ID not matched
The Inverter product code or software
number is different.
Use the copy function for the same
product code and software number.
Table 7.5 Errors during Copy Function (Continued)
Func-
tion
Display Meaning Probable causes Corrective Actions

Table of Contents

Other manuals for YASKAWA Varispeed f7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed f7 and is the answer not in the manual?

YASKAWA Varispeed f7 Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed f7
CategoryInverter
LanguageEnglish

Related product manuals