Standard Inverter Specifications
9-3
400 V Class
* 1. The maximum applicable motor output is given for a standard 4-pole Yaskawa motor. When selecting the actual motor and Inverter, be sure that the Inverter's
rated current is applicable for the motor's rated current.
* 2. A 3-wire transformer is required on the power supply for 12-phase rectification.
Table 9.2 400 V Class Inverters
Model Number CIMR-F7A 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018
Max. applicable motor output
(kW)
*1
0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5
Rated input current (A) 2.2 2.5 4.4 6.4 9.0 15 20 29 37 47
Rated output capacity
(kVA)
1.4 1.6 2.8 4.0 5.8 9.5 13 18 24 30
Rated output current (A) 1.8 2.1 3.7 5.3 7.6 12.5 17 24 31 39
Max. output voltage (V) 3-phase; 380, 400, 415, 440, 460, or 480 VAC (Proportional to input voltage.)
Max. output frequency
(Hz)
CT selected (low carrier, constant torque applications): 150 Hz max.
VT selected (high carrier, variable torque applications): 400 Hz max.
Rated voltage (V)
Rated frequency (Hz)
3-phase, 380, 400, 415, 440, 460 or 480 VAC, 50/60 Hz
Allowable voltage fluctua-
tion
+ 10%, - 15%
Allowable frequency fluc-
tuation
±5%
Measures
for power
supply
harmonics
DC reactor Optional
12-phase rec-
tification
Not possible
Model Number CIMR-F7A 4022 4030 4037 4045 4055
4075 4090 4110
41324160418542204300
Max. applicable motor output
(kW)
*1
22 30 37 45 55 75 90 110 132 160 185 220 300
Rated input current (A) 50 66 83 100 120 165 198 238 286 334 407 557 743
Rated output capacity
(kVA)
34 46 57 69 85 110 140 160 200 230 280 390 510
Rated output current (A) 45 60 75 91 112 150 180 216 260 304 370 506 675
Max. output voltage (V) 3-phase, 380, 400, 415, 440, 460, or 480 VAC (Proportional to input voltage.)
Max. output frequency
(Hz)
CT selected (low carrier, constant torque applications): 150 Hz max.
VT selected (high carrier, variable torque applications): 400 Hz max.
Max. voltage (V)
Rated frequency (Hz)
3-phase, 380, 400, 415, 440, 460, or 480 VAC, 50/60 Hz
Allowable voltage fluctua-
tion
+ 10%, - 15%
Allowable frequency fluc-
tuation
±5%
Measures
for power
supply
harmonics
DC reactor Built in
12-phase rec-
tification
Possible
*2
O
utput rat
i
ngs
300 Hz max.
Power supp
l
y c
h
aracter
i
st
i
cs
Control characteristics
O
utput rat
i
ngs
300 Hz max.
Power supp
l
y c
h
aracter
i
st
i
cs
C
ontro
l
c
h
aracter
i
st
i
cs

Table of Contents

Other manuals for YASKAWA Varispeed f7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed f7 and is the answer not in the manual?

YASKAWA Varispeed f7 Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed f7
CategoryInverter
LanguageEnglish

Related product manuals