APPENDIX 2 LIST OF PARAMETER NUMBERS (Cent’d)
HSPDM
1:
Enable high–speed M function.
o:
Disable high-speed M function.
RWDOUT D4
:1: Provides Rewinding Activate Signal when NC
program is rewound by RESET & REWIND
signal.
0: Provides no Rewinding Activate Signal when
NC program is rewound by RESET & REWIND
signal.
OUTPUT D3
1:
Sets the least output increment at O. 0001 inch
o: Sets the least output increment at O. 001 mm.
SC:R.SOV D2
1: Makes the Spindle override 100% during
tapping.
o:
Does not make the Spindle override 100%
during tapping.
SLT31O
D]
1: Establishes the prohibited area of the Stored
Stroke Limit 3 outside the boundary.
O: Establishes the prohibited area of the Stored
Stroke Limit 3 inside the boundary.
SL”r 210
Do
1: Establishes the prohibited area of the Stored
Stroke Limit 2 outside the boundary.
O: Establishes the prohibited area of the Stored
Stroke Limit 2 inside the boundary.
OF SOCLR: D7
1:
Do not clear OFSOO X, Z by O-9999 ORG.
o:
Clear OFSOO X, Z by O-9999 ORG.
FSA40DCH: D6
1:
Edit FS backward upon FS editing.
o:
Edit FS each time upon FS editing.
PONM97
D5
1: M97 command (calculation of intersection) is
selected at power-on.
o:
M96 command (circular arc) is selected at
power-on.
FEEDCUT: D4
1: With feed when upon tape output from the
NC.
0: Without feed when upon tape output from the
NC.
M30RWD2 D3
1.
..
Rewinding:
operates with M30 if the stand arcl
YASNAC tape reader is connected to the
second RS232C.
o:
No rewinding .
M30RWDl D2
1: Rewinding:
operates with M30 if the standarcl
Y.ASNAC tape reader is connected to the first
RS232C.
o:
NO rewinding.
CVSAVE D1
~:
Does not ciear user macro command variable
#100 thru #149 by reset.
0: Clears user macro common variables #100
thru #140 by reset operation .
ZRNOFS D()
~:
Cancels the commanded block when the second
reference point “by G 30 is commanded during
TOO1 Position Offset or Tool iNose Radius Com–
pensation.
0: <Cancels the blocks following the commanded
block .
ZMOVILK D 7
1: After turning on power, if move command
except by G2S is executed without
returning
~-axis to reference point manually or auto-
matically,
alarm “001” will be caused.
o:
iloes not cause alarm in the same condition
shown above.
YQ.JOVILD D6
1: After turning on power, if move command
except by G28 is ~xecuted without returning
X-axis to reference point manually or auto-
matically, alarm
“001” will be caused.
o: Does not cause alarm .
OTALILK D5
1:
Does not cause an alarm at overtravel.
o: Causes an alarm at overtravel.
HPMUL D4
1:
Sets the value set by #6223 when MANUAL
PULSE MULTIPLY switch is set at x1OO.
o: Regards multiplication factor as x 100 when
MANUAL PULSE MULTIPLY switch is set
at x1OO.
A--8