IM 01E20D01-01E
6-12
6. OUTLINE
Fluid Temperature and Pressure:
The following figures show maximum allowable fluid
pressure for the flowtube. Further fluid pressure should
also be limitted according to flange rating.
For fluid temperature of the explosion proof type, refer to
descriptions of “HAZARDOUS AREA CLASSIFICA-
TION”.
PFA Lining (*1)
General-Purpose Use, Submersible Type, Explosion
proof Type, Remote Flowtube (electrode structure
code 1: Non-replaceable electrode)
Pressure
MPa (psi)
4 (580)
2 (290)
1 (145)
– 0.1 (–14.5)
– 40
(–40)
40
(104)
100
(212)
160
(320)
Temperature °C (°F)
130
(266)
2.5 to 50 mm (0.1 to 2.0 in.) (flange type, wafer type)
65 to 200 mm (2.5 to 8.0 in.) (flange type, wafer type)
250, 300 mm (10, 12 in.) (flange type)
250, 300 mm (10, 12 in.) (wafer type)
350, 400 mm (14, 16 in.) (flange type)
0
(32)
–10
(14)
F18-1.EPS
150
(302)
*1
General-Purpose Use and Explosion proof Type,
Integral Flowmeter (electrode structure code 1:
Non-replaceable electrode)
Pressure
MPa (psi)
4 (580)
2 (290)
1 (145)
0.1 (–14.5)
– 40
(– 40)
40
(104)
100
(212)
Temperature °C (°F)
130
(266)
0
(32)
–10
(14)
2.5 to 50 mm (0.1 to 2.0 in.) (flange type, wafer type)
65 to 200 mm (2.5 to 8.0 in.) (flange type, wafer type)
250, 300 mm (10, 12 in.) (flange type)
250, 300 mm (10, 12 in.) (wafer type)
350, 400 mm (14, 16 in.) (flange type)
F18-2.EPS
*1
*1: For wafer types of 32 mm to 300 mm(1.25 to 12 in.), and
for carbon steel flange types (process connection code:
C
**
) of 50 to 400 mm (2.0 to 16 in.), the minimum tem-
perature is –10°C (14°F).
*2: For fluid temperature of the explosion proof type, refer
to descriptions of “HAZARDOUS AREA CLASSIFI-
CATION”.
General-Purpose Use, Remote Flowtube (electrode
structure code 2: replaceable electrode)
Pressure
MPa (psi)
2 (290)
1 (145)
0.1 (–14.5)
0
(32)
40
(104)
100
(212)
160
(320)
–10
(14)
130
(266)
Temperature °C (°F)
25 to 200 mm (1.0 to 8.0 in.) (flange type, wafer type)
250, 300 mm (10, 12 in.) (flange type)
250, 300 mm (10, 12 in.) (wafer type)
350, 400 mm (14 to 16 in.) (flange type)
F18-3.EPS
General-Purpose Use, Integral Flowmeter (electrode
structure code 2: replaceable electrode)
2 (290)
1 (145)
0.1 (–14.5)
40
(104)
100
(212)
130
(266)
250, 300 mm (10, 12 in.) (flange type)
250, 300 mm (10, 12 in.) (wafer type)
350, 400 mm (14 to 16 in.) (flange type)
25 to 200 mm (1.0 to 8.0 in.) (flange type, wafer type)
Temperature °C (°F)
Pressure
MPa (psi)
0
(32)
–10
(14)
F18-4.EPS
Note: For replaceable electrodes for fluid temperatures of
-10°C (14°F)or less, please contact Yokogawa office.
Sanitary Type (electrode structure code 1:
Non-replaceable electrode)
F18-5.EPS
Temperature °C (°F)
Pressure
MPa (psi)
1(145)
–0.1(–14.5)
15 to 125 mm (0.5 to 5.0 in.) (integral flowmeter)
160
(320)
130
(266)
15 to 125 mm (0.5 to 5.0 in.) (remote flowtube)
0
(32)
–10
(14)
Note: In case of 120 to 160°C (248 to 320°F) of fluid
temperature, please select optional code GH.
Ceramics Lining
General-Purpose Use and Explosion proof Type,
Remote Flowtube (electrode structure code 1:
Non-replaceable electrode)
Pressure
MPa (psi)
Temperature °C (°F)
2.5 to 50 mm (0.1 to 2.0 in.)
80 to 200 mm (3.0 to 8.0 in.)
4 (580)
2 (290)
–0.1 (–14.5)
–10
(14)
0
(32)
100
(212)
180
(356)
F19-1.EPS