4-57
IM DL350-17EN
Commands
1
2
3
4
5
App
Index
:CHANnel<x1>:LIN:SCHannel<x2>:FACTor
Function Sets or queries the scaling coefficient (the value
per bit) of the specified sub channel on a module
that can monitor LIN bus signals.
Syntax
:CHANnel<x1>:LIN:SCHannel<x2>:
FACTor {<NRf>}
:CHANnel<x1>:LIN:SCHannel<x2>:
FACTor?
<x1> = 2, 4
<x2> = 1 to 60
<NRf> = –9.9999E+30 to 9.9999E+30
Example
:CHANNEL4:LIN:SCHANNEL1:FACTOR 2.0
:CHANNEL4:LIN:SCHANNEL1:FACTOR?
-> :CHANNEL4:LIN:SCHANNEL1:
FACTOR 2.000E+00
Description This command is valid when the data type
(:CHANnel<x1>:LIN:SCHannel<x2>:VTYPe) is
set to UNSigned or SIGNed.
:CHANnel<x1>:LIN:SCHannel<x2>:ID
Function Sets or queries the frame ID of the specified sub
channel on a module that can monitor LIN bus
signals.
Syntax
:CHANnel<x1>:LIN:SCHannel<x2>:
ID {<String>}
:CHANnel<x1>:LIN:SCHannel<x2>:ID?
<x1> = 2, 4
<x2> = 1 to 60
<String> = “0” to “3F”
Example
:CHANNEL4:LIN:SCHANNEL1:ID “1”
:CHANNEL4:LIN:SCHANNEL1:ID?
-> :CHANNEL4:LIN:SCHANNEL1:ID “1”
Description If a string outside the range is specified, error
151, “Invalid string data,” will occur.
:CHANnel<x1>:LIN:SCHannel<x2>:INPut
Function Sets or queries the input ON/OFF state of the
specified sub channel on a module that can
monitor LIN bus signals.
Syntax
:CHANnel<x1>:LIN:SCHannel<x2>:
INPut {<Boolean>}
:CHANnel<x1>:LIN:SCHannel<x2>:INPut?
<x1> = 2, 4
<x2> = 1 to 60
Example
:CHANNEL4:LIN:SCHANNEL1:INPUT ON
:CHANNEL4:LIN:SCHANNEL1:INPUT?
-> :CHANNEL4:LIN:SCHANNEL1:INPUT ON
:CHANnel<x1>:LIN:SCHannel<x2>:LABel
Function Sets or queries the label string of the specified
sub channel on a module that can monitor LIN
bus signals.
Syntax
:CHANnel<x1>:LIN:SCHannel<x2>:
LABel {<String>}
:CHANnel<x1>:LIN:SCHannel<x2>:LABel?
<x1> = 2, 4
<x2> = 1 to 60
<String> = Up to 16 characters
Example
:CHANNEL4:LIN:SCHANNEL1:
LABEL “CH4_1”
:CHANNEL4:LIN:SCHANNEL1:LABEL?
-> :CHANNEL4:LIN:SCHANNEL1:
LABEL “CH4_1”
:CHANnel<x1>:LIN:SCHannel<x2>:OFFSet
Function Sets or queries the scaling coefficient (the offset)
of the specified sub channel on a module that can
monitor LIN bus signals.
Syntax
:CHANnel<x1>:LIN:SCHannel<x2>:
OFFSet {<NRf>}
:CHANnel<x1>:LIN:SCHannel<x2>:
OFFSet?
<x1> = 2, 4
<x2> = 1 to 60
<NRf> = –9.9999E+30 to 9.9999E+30
Example
:CHANNEL4:LIN:SCHANNEL1:OFFSET 1.0
:CHANNEL4:LIN:SCHANNEL1:OFFSET?
-> :CHANNEL4:LIN:SCHANNEL1:
OFFSET 1.000E+00
Description This command is valid when the data type
(:CHANnel<x1>:LIN:SCHannel<x2>:VTYPe) is
set to UNSigned or SIGNed.
:CHANnel<x1>:LIN:SCHannel<x2>:POSiti
on
Function Sets or queries the vertical position value of
the specified sub channel on a module that can
monitor LIN bus signals.
Syntax
:CHANnel<x1>:LIN:SCHannel<x2>:
POSition {<NRf>}
:CHANnel<x1>:LIN:SCHannel<x2>:
POSition?
<x1> = 2, 4
<x2> = 1 to 60
<NRf> = –5.00 to 5.00 (in 0.01 div steps)
Example
:CHANNEL4:LIN:SCHANNEL1:POSITION 1.0
:CHANNEL4:LIN:SCHANNEL1:POSITION?
-> :CHANNEL4:LIN:SCHANNEL1:
POSITION 1.00
4.6 CHANnel Group