<9. General Specications>
9-2
IM 01C25F01-01E
Output“◊”
For 4 to 20 mA output
(Output signal code D, E and J)
Two wire 4 to 20 mA DC output with digital
communications, linear or square root
programmable. BRAIN or HART FSK protocol
are superimposed on the 4 to 20 mA signal.
Output range: 3.6 mA to 21.6 mA
Output limits conform to NAMUR NE43 can be
pre-set by option C2 or C3.
For 1 to 5 V output
(Output signal code Q)
Three or four wire low power 1 to 5 V DC output
with HART, linear or square root programmable.
HART protocol is superimposed on the 1 to 5 V
DC signal.
Output range: 0.9 V to 5.4 V DC
FailureAlarm“◊”
For 4 to 20 mA output
(Output signal code D, E and J)
Analog output status at CPU failure and
hardware error;
Up-scale: 110%, 21.6 mA DC or more
(standard)
Down-scale: –5%, 3.2 mA DC or less
For 1 to 5 V output
(Output signal code Q)
Analog output status at CPU failure and
hardware error;
Up-scale: 110%, 5.4 V DC or more
(standard)
Down-scale:−5%,0.8VDCorless
Damping Time Constant (1st order)
Amplierdampingtimeconstantisadjustable
from 0 to 100.00 seconds and added to
response time.
Note: ForBRAINprotocoltype,whenamplierdamping
is set to less than 0.5 seconds, communication
may occasionally be unavailable during the
operation, especially while output changes
dynamically. The default setting of damping
ensures stable communication.
UpdatePeriod“◊”
45 ms
Zero Adjustment Limits
Zero can be fully elevated or suppressed, within
the lower and upper range limits of the capsule.
ExternalZeroAdjustment“◊”
External Zero is continuously adjustable with
0.01% incremental resolution of span. Re-range
can be done locally using the digital indicator
with range-setting switch.
Integral Indicator (LCD display)
5-digit Numerical Display, 6-digit Unit Display
and Bar graph.
Theindicatoriscongurabletodisplayoneor
up to four of the following variables periodically.;
Pressure in %, Scaled pressure, pressure in
Engineering unit.
See “Setting When Shipped” for factory setting.
Burst Pressure Limits
EJ510 and EJ530
Capsule Pressure
A, B, C 30 MPa (4350 psi)
D * 132 MPa (19100 psi)
*: 182 MPa (26300 psi) for EJA510E and EJA530E when
/HGisspecied.
EJX610A and EJX630A
Capsule Pressure
A, B, C 50 MPa (7200 psi)
D 182 MPa (26300 psi)
Normal Operating Condition
(Selected features may affect limits.)
Ambient Temperature Limits
–40 to 85°C (–40 to 185°F)
–30 to 80°C (–22 to 176°F) with LCD display
Process Temperature Limits
–40 to 120°C (–40 to 248°F)
Ambient Humidity Limits
0 to 100% RH
Working Pressure Limits (Silicone oil)
Maximum Pressure Limits
Pressure
Capsule
EJ510 EJ530
A 200 kPa abs (29 psia) 200 kPa (29 psig)
B 2 MPa abs (290 psia) 2 MPa (290 psig)
C 10 MPa abs (1450 psia) 10 MPa (1450 psig)
D* 50 MPa abs (7200 psia) 50 MPa (7200 psig)
*: 70 MPa(10150 psi) for EJA510E and EJA530E when
/HGisspecied.
Pressure
Capsule EJX610A EJX630A
A 200 kPa abs (29 psia) 200 kPa (29 psi)
B 2 MPa abs (290 psia) 2 MPa (290 psi)
C 10 MPa abs (1450 psia) 10 MPa (1450 psi)
D 70 MPa abs (10150 psia) 70 MPa (10150 psi)
Minimum Pressure Limit
See graph below