EasyManua.ls Logo

YOKOGAWA EJX530A - Iecex Certification

YOKOGAWA EJX530A
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
<2. Handling Cautions>
2-13
IM 01C25F01-01E
2.9.4 IECExCertication
EJX Series pressure transmitters with optional
code /SU21 can be selected the type of
protection (IECEx Intrinsically Safe Ex ia, Ex ic
orameproof)foruseinhazardouslocations.
Note 1. For the installation of this transmitter,
once a particular type of protection is
selected, any other type of protection
cannot be used. The installation must be in
accordance with the description about the
type of protection in this instruction manual.
Note 2. For combined approval types, once a
device of multiple approval type is installed,
it should not be re-installed using any
other approval types. Apply a permanent
mark in the check box of the selected
approvaltypeonthecerticationlabelon
the transmitter to distinguish it from unused
approval types.
a. IECEx Intrinsically Safe Ex ia
Caution for IECEx Intrinsically safe Ex ia.
Note 1. EJX/EJA-E series pressure transmitters
with optional code /SU21 are applicable for
use in hazardous locations
No. IECEx DEK 11.0081X
Applicable Standard:
IEC 60079-0:2011, IEC 60079-11:2011
Ex ia IIC T4 Ga
Ambient Temperature: –50 to 60°C
Max. Process Temp.: 120°C
Enclosure: IP66/IP67
To satisfy IP66 or IP67, apply waterproof
glands to the electrical connection port.
Note 2. Electrical Data
Maximum Input Voltage (Ui) = 30 V
Maximum Input Current (Ii) = 200 mA
Maximum Input Power (Pi) = 0.9 W
(linear source)
Maximum Internal Capacitance (Ci) = 27.6 nF
MaximumInternalInductance(Li)=0μH
Whenthelightningprotectoroptionisspecied,
the apparatus is not capable of withstanding the
500V insulation test required by IEC60079-11.
This must be taken into account when installing
the apparatus.
Note 3. Installation
In any safety barrier used output current
must be limited by a resistor ‘R’ such that
Io=Uz/R.
• ThesafetybarriermustbeIECExcertied.
Input voltage of the safety barrier must be
less than 250 Vrms/Vdc.
• Theinstrumentmodicationorparts
replacement by other than authorized
representative of Yokogawa Electric
Corporation is prohibited and will void IECEx
certication.
F0215.ai
EJX/EJA-E Series
Pressure Transmitters
IECEx certified
Safety Barrier
Supply
Hazardous Location Nonhazardous Location
+
+
[Ex ia]
Group IIC, Zone 0
(*1)
*1: When using non isolation barrier,
connect (*1) to IS barrier system.
Note4. SpecicConditionofUse
WARNING
Electrostatic charge may cause an explosion
hazard. Avoid any actions that cause the
generation of electrostatic charge, such as
rubbing with a dry cloth on coating face of
the product.
When the enclosure of the pressure
transmitter is made of aluminum, if it is
mounted in an area where the use of
EPL Ga equipment is required, it must be
installed such, that, even in the event of rare
incidents, ignition sources due to impact and
friction sparks are excluded.
Electrostatic charges on the coated parts of
Pressure Transmitter shall be avoided.
b. IECEx Intrinsically Safe Ex ic
Caution for IECEx Intrinsically safe Ex ic.
Note 1. EJX/EJA-E series pressure transmitters
with optional code /SU21 are applicable for
use in hazardous locations
No. IECEx DEK 13.0061X
Applicable Standard: IEC 60079-0:2011,
IEC 60079-11:2011

Table of Contents

Related product manuals