EasyManua.ls Logo

YOKOGAWA WT332E - Page 65

YOKOGAWA WT332E
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-31
IM WT310E-02EN
Making Preparations for Measurements
1
2
3
4
5
6
7
App
Index
Wiring Example of a Single-Phase, Three-Wire System (1P3W)
The wiring is connected to input elements 1 and 3.
±
±C
V
±
V
±
C
N
SOURCE
SOURCE
LOAD
LOAD
C
±
±
Element 1
(V1, A1)
V
N
Element 3
(V3, A3)
U1
U3
I3
I1
C
±
±
V
Wiring Example of a Three-Phase, Three-Wire System (3P3W)
The wiring is connected to input elements 1 and 3.
Measure the line voltage using S-phase power as the reference.
SOURCE
LOAD
I1
±C
±
I3
±
C
U1
±
V
U3
V
R
ST
SOURCE LOAD
Element 1
(V1, A1)
R
S
T
Element 3
(V3, A3)
C
±
±
V
C
±
±
V
Wiring Example of a Three-Phase, Four-Wire System (3P4W)
Applies to the WT333E.
The wiring is connected to input elements 1, 2, and 3.
SOURCE
LOAD
I1
±C
±
I3
±
C
U1
±
V
U3
V
R
N
ST
SOURCE
Element 1
(V1, A1)
R
S
T
N
Element 2
(V2, A2)
LOAD
Element 3
(V3, A3)
U2
±
V
I2
±C
C
±
±
V
C
±
±
V
C
±
±
V
2.9 Wiring the Circuit under Measurement for Direct Input

Table of Contents

Related product manuals