Overview of YORK's split-system heat pump technology and manufacturing standards for commercial markets.
Details heavy-duty compressor, crankcase heater, overload protection, and reversing valve.
Describes insulated cabinet, copper tube/aluminum fin coil, centrifugal blower, motor, and filter-drier.
Discusses lightweight nature, lifting methods, sound levels, and condensate management for outdoor units.
Details single cabinet design, vertical/horizontal positioning, and accessory usage for indoor units.
Provides air temperature parameters for indoor and outdoor coils during cooling and heating cycles.
Specifies maximum vertical rise, total length, and other limitations for refrigerant piping installation.
Explains coil circuity for performance and subcooling, allowing flexible unit mounting and piping configurations.
Presents detailed cooling capacities (Total, Sensible) and power input (KW) for various temperature conditions.
Lists heating capacities (MBH, KW) for heat pump operation at various outdoor and indoor air temperatures.
Details nominal heating capacities (KW, MBH) for electric heat accessory models at different voltage inputs.
Provides motor HP, blower HP, pulley dimensions, belt designation, and RPM ranges for blower operation.
Presents performance data (CFM, ESP, BHP, KW) for various RPMs and static pressures for the supply air blower.
Lists static pressure resistance (IWG) for electric heat, supply air plenum, and return air grille accessories.
Describes electric heaters, supply air plenums, return air grilles, base sections, and thermostat options.
Specifies minimum required clearances for overhead, front, sides, and rear of the outdoor unit for installation.
Provides approximate center of gravity dimensions (A, B, C, D) for different outdoor unit sizes.
Details minimum clearances for indoor units and shows added dimensions for electric heaters, plenums, and bases.
Outlines wiring terminals for indoor/outdoor units, thermostat connections, and power supply requirements.
Provides dimensions for the electric heater accessory, including wiring harness and power supply access openings.
Shows dimensions for the supply air plenum, including knockout locations for power and control wiring.
Provides dimensions for the return air grille accessory.
Shows dimensions for the base accessory, used to raise the indoor unit.
Provides electrical specifications for outdoor units, including compressor, fan motor, power supply, and wiring.
Details electrical data for indoor units, including blower motor, electric heat, power supply, and wiring.
Specifies wire size requirements based on circuit length for control wiring between indoor and outdoor units.