30
Wiring Schematics cont.
Aur
ora BA
SE with 5 Speed ECM and IntelliStart
Tra
ns
f
orme
r
24V
To P
2
on
El
ec
t
r
ic
H
e
at
B
oar
d
RV
CC
HP
Condensate
Bl
ack
Bl
ack
Bl
ue
Bl
ue
LP
T
Y
ellow
Y
ellow
FP
1
Orange
Orange
RV
Bl
ack
(15
)
Vi
ol
et(
14)
Green(11)
Br
o
w
n(2
3)
NO
T
E 1
Bl
ack
/W
hi
t
e
Y
ellow
Red
208V
1
C
2
4
3
2
Bl
ack
(21
)
Bl
ack
(20
)
PB
2
1
3
2
Bl
ue
240V
Bl
ack
Ultra
Tech
Dual Cap
acity
Unit
s Only
RCP
CS
Bl
ue
(16
)
Bl
ue
(1
8)
CC
T2
T1
Comp
r
esso
r
C
R
S
G
L1
L2
Bl
ack
20
8-23
0/60
/1
Un
it Pow
er
S
upp
ly
Vi
ol
et(
7)
Red
Tan
(
6)
Bl
ack
(3)
Bl
ack
(2)
Cap
Ex
t
Pump
1
/
2 h
p
To
tal
208
-230/60
/1
Pum
p
G
1
2
PB
1
1
2
Pum
p
Vi
ol
et(
8)
NOTE 2
Gray/Whit
e(4)
Black/Whi
t
e(5)
Thermos
tat
R
C
Y1
O
DH
Y2
G
W
LO
Ci
rc
ui
t
Br
e
a
ker
Ci
rc
ui
t
Br
e
a
ker
Op
Ɵ
on
al Intern
al
Ho
t Wat
er Ge
ne
ra
Ɵ
on
P
ump
1
5A
5A
DHW
Pum
p
Bl
ue
H
ot W
a
te
r
Limit
Switch
130°
F
Bl
ue
1
2
3
Pur
pl
e
T
raditional
Th
e
r
mo
s
tat
C
ommun
ic
ating
T
hermostat
AI
D
Tool
Cabinet
HW S
wit
ch
1
2
3
L
N
G
C
4
5
Gr
ee
n
Orange
Br
o
w
n
Gr
ay
(30
)
Tan
(3
1
)
Red(32)
Bl
ue
(3
3)
Bl
ack
(35
)
NOTE 3
NOTE 4
Tan
(
6)
Run Winding
Ac
tive
St
art
Commo
n
In
tel
li
Star
t
Red
Bl
ack
Pi
nk
Bl
ack
Bl
ue
Bl
ue
Bl
ack
(2
2)
5 Sp
ee
d
ECM
Bl
o
wer M
o
t
o
r
Bl
ack
CFM
P13
P4
SW
1
P5
JW
2
P9
LO
O/B
Y2
W
DH
P8
P7
RS485 NET
RS485 NE
T
P6
RS485 EXP
P3
SW
2
On
Fut
u
r
e U
se
L Out
put
T
y
pe
CC – Dual/
Single
Ac
c – D
i
p 5
Ac
c – D
i
p 4
RV –
B/O
FP
2
– 1
5
°F
/30
°F
FP1 – 15
°F
/30
°F
Com1
LED5
Com2
LED5
Test
M
ode
F1-3A
P1
C
PW
M
1
2
3
4
5
6
7
8
ALM
ALG
ACC COM
ACC NO
ACC NC
R
C
G
Y1
EH
2
C
EH
1
C
CO
C
R
-
+
C
R-
+
Of
f
Faul
t
LED1
R
St
atus
LED3
Conf
ig
LED2
CC2
CC
F
C
R
F
F
G
CC
CCG
CC2
HI
CC2
LO
CC2
G
RE
V
R
E
V
FP
1
FP
1
FP
2
FP
2
LP
S
LP
S
H
P
SH
PS
Auro
ra Ba
s
e
Contr
ol
(ABC
)
K1-RV
Relay
K2-CC Rel
ay
K3-CC2 Relay
K4-Fan Relay
K5-A
larm
Relay
K6-A
c
c
Relay
F
R
C
CC
G
Y1
C
R
ES
LS
P2
EH
1
Y
G
G
G
Wa
ter
S
ole
no
id
(s
ee
Op
en
L
o
o
p
Gr
ou
n
d
wat
er Sy
s
t
ems
sec
Ɵ
on)
47
0
470
Re
sist
or
Bl
ack
Gr
een/Ye
ll
ow
LX SERIES INST
ALLA
TION MANUAL
29
31
Table of Contents
Table of Contents
3
Model Nomenclature
4
General Installation Information
5
Closed Loop Ground Source Systems
11
Open Loop Ground Water Systems
12
Hot Water Generator Connections
13
Electrical Connections
15
Electronic Thermostat Installation
16
Auxiliary Heat Ratings
17
Auxiliary Heat Electrical Data
17
Electrical Data
17
Blower Performance Data
18
Dimensional Data
19
Physical Data
21
The Aurora™ Control System
22
Reference Calculations
26
Legend
27
Wiring Schematics
28
Unit Startup
32
036 Operating Parameters
34
Pressure Drop
38
Compressor and Thermistor Resistance
39
Refrigerant Circuit Guideline
40
Heat of Extraction/Rejection
41
Correction Factor Tables
42
Antifreeze Corrections
43
Troubleshooting
43
Preventive Maintenance
46
Replacement Procedures
46
Service Parts List
47
Revision Guide
49
Other manuals for York LX series
Owner's Manual
56 pages
Technical Guide
192 pages
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the York LX series and is the answer not in the manual?
Ask a question
York LX series Specifications
General
Refrigerant
R-410A
Series
LX
Cooling Capacity
1.5 to 5 tons
Warranty
10-year limited warranty
Sound Level
As low as 72 dBA (depending on model)
Related product manuals
York LATITUDE Series
34 pages
York 36
44 pages
York MV
12 pages
York SAC
17 pages
York D1EB036
20 pages
York J Series
92 pages
York 20 Series
68 pages
York DC SERIES
70 pages
York EMBASSY Series
20 pages
York AFFINITY SERIES
40 pages
York YUFE24BYTM-MO-X
110 pages
York MILLENNIUM STYLE A
16 pages