CNA#14) is active. When set to 100% the speed reduction is ineffective.
11) CUTBACK SPEED 3
(Standard Version only). Typically from 10% to 100%. It determines the
percentage of the max speed applied when the cutback switch 3 (SR#3 on
CNA#15) is active. When set to 100% the speed reduction is ineffective.
12) H&S CUTBACK
Typically from 10% to 100%. It determines the percentage of the max speed
applied when the Hard & Soft function (H&S switch on CNB#4) is active.
When set to 100% the speed reduction is ineffective.
13) FREQUENCY CREEP
Hz value. This is the minimum speed applied when the forward or reverse
switch is closed, but the accelerator at its minimum.
14) MAXIMUM CURRENT
Level 0 to 9. This changes the maximum current of the inverter. At level 9 the
nominal maximum current is supplied; at level 0 the current is almost half of
its nominal value (see the table).
15) INCHING SPEED
(Standard version only because the inching switches are used for the Lifting
and Lowering switches in the MDI-PRC version). Hz value. It determines the
speed when the "Inching function" is active (see SET INPUT#2, SET
INPUT#3 in “Set options” submenu).
16) INCHING TIME
(Standard version only because the inching switches are used for the Lifting
and Lowering switches in the MDI-PRC version). Level 0 to 9. It determines
the during time when the "Inching function" is active.
17) AUXILIARY TIME
Time units value (seconds). For the encoder version, it determines the time
duration the truck is kept on the ramp if the STOP ON RAMP option is ON.
18) MIN VALVE 1
(MDI-PRC version only). 0 to 255 digit. This parameter determines the
minimum voltage applied on the EVP1 when the position of the potentiometer
on CNA#18 is at the minimum. This parameter is not effective if the EVP1 is
programmed like a On/Off valve (see VALVE 1 TYPE in “Set options”
submenu). The EVP1 is connected on the pin 8 of the MDI-PRC (see TRUCK
TYPE in “Set options” submenu for the handling).
19) MIN VALVE 2
(MDI-PRC version only). 0 to 255 digit. This parameter determines the
minimum voltage applied on the EVP2 when the position of the potentiometer
on CNA#18 is at the minimum. This parameter is not effective if the EVP2 is
programmed like a On/Off valve (see VALVE 2 TYPE in “Set options”
submenu). The EVP2 is connected on the pin 9 of the MDI-PRC (see TRUCK
TYPE in “Set options” submenu for the handling).
20) MAX VALVE 1
(MDI-PRC version only). 0 to 255 digit. This parameter determines the
maximum voltage applied on the EVP1 when the position of the