EasyManua.ls Logo

Zapi AC0 - Parameter Regulation: Standard Version

Zapi AC0
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 37
4.5 PARAMETER REGULATION: STANDARD VERSION
The following parameters can be modified:
1 ACC DELAY: determines the acceleration ramp.
2 RELEASE BRAKING: controls the deceleration ramp when the travel request
is released.
3 INVERSION BRAKING: controls the deceleration ramp when the direction
switch is inverted during travel..
4 PEDAL BRAKING: determines the deceleration ramp when the travel
request is released and the brake pedal switch is
closed.
5 SPEED LIMIT BRAKING: deceleration ramp when the pedal position is changed
but not completely released.
6 BRAKE CUTBACK: determines the deceleration ramp when the speed
reduction input becomes active and the motor slow
down.
7 MAX SPEED FORWARD: determines the maximum speed in forward direction.
8 MAX SPEED BACKWARD: determines the maximum speed in backward direction.
9 CUTBACK SPEED 1: speed reduction when the cutback switch 1 is active.
10 CUTBACK SPEED 2: speed reduction when the cutback switch 2 is active.
11 CUTBACK SPEED 3: speed reduction when the cutback switch 3 is active.
12 H&S CUTBACK: speed reduction when the Hard&Soft switch is active.
13 FREQUENCY CREEP: minimum speed when the forward or reverse switch is
closed, but the accelerator is on a minimum
position.
14 MAXIMUM CURRENT: this changes the maximum current of the inverter.
15 INCHING SPEED: determines the speed in inching function.
16 INCHING TIME: determines the time of the inching function.
17 AUXILIARY TIME: determines the time that the truck is hold on the ramp if
the "stop on ramp" option is ON.
The following table shows the different values at which the parameters can be set.

Table of Contents