4.4.b MDI PRC Version
SUBMENU "SET OPTIONS"
1 TILLER SWITCH
- HANDLE input B3 is managed as a tiller input.
- SEAT input B3 is managed as a seat input.
2 SET INPUT #1
- OPTION #1: input A13 is managed as a motor thermal sensor analog input.
- OPTION #2: input A13 is managed as a cutback speed input (SR#1 - HW
modification required).
- OPTION #3: input A13 is managed as an handbrake input (HW modification
required).
3 SET INPUT #4
- BELLY: input B7 is managed as a belly input.
- BRAKE: input B7 is managed as a service brake input.
- EX. HYDRO: input B7 is managed as a "Exclusive Hydro" input.
4 HOUR COUNTER
- RUNNING: the counter registers travel time only.
- KEY ON: the counter registers when the "key" switch is closed.
5 BATTERY CHECK
- ON: the battery discharge level check is carried out; when the
battery level reaches 10%, an alarm is signalled and the
maximum current is reduced to the half of the programmed
value.
- OFF: the battery discharge level check is carried out but no alarm is
signalled.
6 HYDRO KEY ON
- ON / OFF: if this option is programmed ON the traction inverter manages
an hydraulic steering function when the "key" is switched ON
(only if the "aux output #1" option is programmed as "hydro
contactor" or as "exclusive hydro").
7 STOP ON RAMP
- ON: the stop on ramp feature (truck electrically hold on a ramp) is
managed for a time established by "auxiliary time" parameter.
After this time, the behaviour depends on the "aux output #1"
option programmation (see also the following table).
- OFF: the stop on ramp feature is not performed.