19) SEAT SWITCH: the level of the Seat Microswitch digital entry.
ON / +VB = active entry of closed switch.
OFF / GND = non active entry of open switch.
or:
TILLER SWITCH: the level of the Tiller Microswitch digital entry. ("Tiller switch" option
set as "Handle").
ON / +VB = active entry of closed switch.
OFF / GND = non active entry of open switch.
20) H&S CUTBACK: the level of the Hard&Soft Microswitch digital entry.
ON / +VB = active entry of closed switch.
OFF / GND = non active entry of open switch.
21) QUICK INVERSION: the level of the Quick Inversion Microswitch digital entry. ("Set
Input #4" option set as "Belly").
ON / +VB = active entry of closed switch.
OFF / GND = non active entry of open switch.
or:
BRAKE SWITCH: the level of the Brake Pedal Microswitch digital entry. ("Set Input
#4" option set as "Brake").
ON / +VB = active entry of closed switch.
OFF / GND = non active entry of open switch.
or:
EXCLUSIVE HYDRO: the level of the Exclusive Hydro Microswitch digital entry. ("Set
Input #4" option set as "Ex.Hydro").
ON / +VB = active entry of closed switch.
OFF / GND = non active entry of open switch.
22) CUTBACK SWITCH 1: the level of the Speed Reduction Microswitch 1. ("Set Input
#1" option set as "Present").
ON / GND = active entry of open switch.
OFF / +VB = non active entry of closed switch.
or:
HAND BRAKE: the level of the Hand Brake. ("Set Input #1" option set as "Option #1").
ON / GND = active entry of open switch.
OFF / +VB = non active entry of closed switch.
23) CUTBACK SWITCH 2: the level of the Speed Reduction Microswitch 2. ("Set Input
#2" option set as "Present").
ON / GND = active entry of open switch.
OFF / +VB = non active entry of closed switch.
or:
INCHING FORW: the level of the Inching Microswitch - Forward direction. ("Set Input
#2" option set as "Option #1").
ON / +VB = active entry of closed switch.
OFF / GND = non active entry of open switch.