Configuration
Standard Control Panel Parameters
3/12/09 Xi4 User Guide P1009874-001
Select Format Convert
Selects the bitmap scaling factor. The first number is the original dots per
inch (dpi) value; the second, the dpi to which you would like to scale.
Default Value: NONE
Selections: NONE, 150 300, 150 600, 200 600, 300 600
To change the value shown:
1. Press PLUS (+) or MINUS (-) to scroll through the options.
Select Idle Display
This parameter selects the LCD options for the real-time clock.
Note • If the default value is not selected, pressing PLUS (+) or
MINUS (-) briefly displays the firmware version of the printer.
Default Value: FIRMWARE (FW) VERSION
Selections: MM/DD/YY (24HR), MM/DD/YY (12HR),
DD/MM/YY (24HR), DD/MM/YY (12HR), FW VERSION
To change the value shown:
1. Press PLUS (+) or MINUS (-) to scroll through the options.
Set Real-Time Clock (RTC) Date
This parameter allows you to set the date following the convention selected
in
IDLE DISPLAY.
To change the value shown:
1. Press MINUS (-) to move to the next digit position.
2. Press PLUS (+) to change the value of the digit.
Set RTC Time
This parameter allows you to set the time following the convention selected
in
IDLE DISPLAY.
To change the value shown:
1. Press MINUS (-) to move to the next digit position.
2. Press PLUS (+) to change the value of the digit.
Specify Password Level
This parameter allows you to select whether certain factory-selected menu
items or all menu items are password protected.
Default Value: SELECTED ITEMS
Selections: SELECTED ITEMS, ALL ITEMS
1. Press PLUS (+) or MINUS (-) to toggle between the options.
Table 9 • Printer Parameters (Sheet 21 of 22)
Language/Parameter
Action/Explanation