Do you have a question about the ZEEWEII DSO3D12 and is the answer not in the manual?
Describes primary functions of each button.
Details secondary functions accessed via the Shift key.
Covers high voltage, probe, charging, and measurement safety.
Instructions for powering on/off and charging the device.
Using the Auto function for rapid waveform display setup.
Adjusting vertical sensitivity and horizontal time base.
Using the oscilloscope's signal generator for testing.
Guide to operating the built-in multimeter function.
Enabling, disabling, and prioritizing dual channels.
Steps for calibrating probes for accurate measurements.
Probe bandwidth differences and maximum voltage ratings.
Advice on input capacitance and measuring high voltages.
Adjusting vertical sensitivity and waveform position.
Understanding and adjusting the time base for waveform display.
Moving waveforms horizontally in stop mode.
Purpose and types of waveform triggering.
Setting trigger level and selecting trigger source.
Overview of Auto, Normal, and Single trigger modes.
Using 50% for reset and capturing screenshots.
Procedure for capturing single events with Single trigger.
Accessing and managing stored screenshots.
Using the built-in signal generator.
Using cursors for precise waveform measurements.
Coupling and probe settings within the channel menu.
Available automatic measurement options.
Settings for trigger mode, type, level, and source.
Configuring waveform persistence and roll modes.
System settings like FFT, calibration, and auto-shutdown.
List of commands and functions for the voice assistant.
How to reset the device to its initial state.
Differences in attenuation, bandwidth, and usage of probes.
Explanation for slower waveform refresh at higher time bases.
Steps for measuring DC power voltage.
Safety and steps for measuring 220V mains voltage.
Procedure for measuring audio signals.
Measuring main board communication or bus signals.
Technique for measuring power supply ripple.
| Bandwidth | 100 MHz |
|---|---|
| Channels | 2 |
| Vertical Resolution | 8 bits |
| Vertical Sensitivity | 2 mV/div to 10 V/div |
| Timebase Range | 5 ns/div to 50 s/div |
| Power Supply | 100-240 V AC, 50/60 Hz |
| FFT | Yes |
| Sampling Rate | 1 GS/s |
| Trigger Modes | Edge, Pulse, Video |
| Display | 7-inch TFT LCD |
| Interface | USB Host, USB Device |
| Input Impedance | 1 MΩ |
| Waveform Capture Rate | 50, 000 wfms/s |
| Probe | 2 x Passive Probes (1X/10X switchable) |
| Operating System | Embedded |