DSO3D12
User’s Manual
Designed by ZEEWEII
DIGITAL OSCILLOSCOPE
Question and Answer IconNeed help?

Do you have a question about the ZEEWEII DSO3D12 and is the answer not in the manual?

Summary

Buttons Function

Default Button Functions

Describes primary functions of each button.

Shift + Button Functions

Details secondary functions accessed via the Shift key.

Safety Precautions

General Safety Guidelines

Covers high voltage, probe, charging, and measurement safety.

Quick Start Guide

Power and Charging

Instructions for powering on/off and charging the device.

Automatic Setup (Auto)

Using the Auto function for rapid waveform display setup.

Sensitivity and Time Base Adjustment

Adjusting vertical sensitivity and horizontal time base.

Built-in Signal Generator

Using the oscilloscope's signal generator for testing.

Multimeter Usage

Guide to operating the built-in multimeter function.

Channel Operations

Dual Channel Management

Enabling, disabling, and prioritizing dual channels.

Probes and Calibration

Probe Calibration Procedure

Steps for calibrating probes for accurate measurements.

Probe Specifications and Usage

Probe Bandwidth and Voltage Limits

Probe bandwidth differences and maximum voltage ratings.

Probe Usage Tips

Advice on input capacitance and measuring high voltages.

Display System

Vertical Sensitivity and Position

Adjusting vertical sensitivity and waveform position.

Horizontal System

Time Base Settings

Understanding and adjusting the time base for waveform display.

Horizontal Waveform Movement

Moving waveforms horizontally in stop mode.

Trigger System

Trigger Functionality

Purpose and types of waveform triggering.

Trigger Level and Source

Setting trigger level and selecting trigger source.

Trigger Modes Explained

Overview of Auto, Normal, and Single trigger modes.

Operation Guide

Quick Operations (50%, Screenshot)

Using 50% for reset and capturing screenshots.

Single Trigger Capture

Procedure for capturing single events with Single trigger.

Viewing Saved Images

Accessing and managing stored screenshots.

Advanced Features

Signal Generator Operation

Using the built-in signal generator.

Cursor Measurements

Using cursors for precise waveform measurements.

Menu System

Channel Menu Options

Coupling and probe settings within the channel menu.

Measurement Parameters

Available automatic measurement options.

Trigger Menu Configuration

Settings for trigger mode, type, level, and source.

Display and Settings

Display Options (Persistence, Roll)

Configuring waveform persistence and roll modes.

Device Settings and Calibration

System settings like FFT, calibration, and auto-shutdown.

Voice Assistants

Voice Assistant Commands

List of commands and functions for the voice assistant.

Q & A

Device Reset Procedure

How to reset the device to its initial state.

Probe 1 X vs 10 X Comparison

Differences in attenuation, bandwidth, and usage of probes.

Waveform Refresh Rate

Explanation for slower waveform refresh at higher time bases.

Measuring DC Power Voltage

Steps for measuring DC power voltage.

Measuring 220 V Mains

Safety and steps for measuring 220V mains voltage.

Measuring Audio Signal

Procedure for measuring audio signals.

Measuring Communication Signals

Measuring main board communication or bus signals.

Measuring Power Supply Ripple

Technique for measuring power supply ripple.

ZEEWEII DSO3D12 Specifications

General IconGeneral
Bandwidth100 MHz
Channels2
Vertical Resolution8 bits
Vertical Sensitivity2 mV/div to 10 V/div
Timebase Range5 ns/div to 50 s/div
Power Supply100-240 V AC, 50/60 Hz
FFTYes
Sampling Rate1 GS/s
Trigger ModesEdge, Pulse, Video
Display7-inch TFT LCD
InterfaceUSB Host, USB Device
Input Impedance1 MΩ
Waveform Capture Rate50, 000 wfms/s
Probe2 x Passive Probes (1X/10X switchable)
Operating SystemEmbedded