EasyManua.ls Logo

Zepro ZU 75-110 - Lubrication and Oil Level Check; Lubrication; Oil Level Check

Default Icon
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Z 45/75-90/110
56
Lubrication and oil level check
www.zepro.com
1
2
5
3
6
4
8
7
9
10
11
12
Image 67. Lubrication points
8 Lubrication and oil level check
The following lubrication points must be greased on installation. They must then be lubricated at least 4
times a year.
8.1 Lubrication
NOTE!
Use LE lubricant 4622 or the equivalent.
1. Right tilt cylinder, at lower bearing.
2. Right lift cylinder, at lower bearing.
3. Lift arm right side, at lower bearing.
4. Left lift cylinder, at lower bearing.
5. Left tilt cylinder, at lower bearing.
6. Lift arm left side, at lower bearing.
7. Left tilt cylinder, at upper bearing.
8. Right tilt cylinder, at upper bearing.
9. Lift arm right side, at upper bearing
10. Right lift cylinder, at upper bearing.
11. Left lift cylinder, at upper bearing.
12. Lift arm left side, at upper bearing.
8.2 Oil level check
Checktheuidlevelinthetankduringmaintenance,topupifnecessary.Themarkingonthehydraulictank
indicatesthetypeofhydraulicuidused.Mineralhydraulicuid,productno.21963(1litre),orbiodegradable
syntheticuid,productno.22235(1litre).

Table of Contents