147
Updating the Console Configuration
Define Patch Groups
Predefined sets of channels are configured for Group Patch using the Group Patch
Definition menu. These patch groups are activated from the “Patch Groups” menu
selection of the “Group Menu” menu. When the Group Patch Definition menu is selected,
the Miscellaneous Menu is replaced with a list of 16 patch group buttons.
To define a group, press the desired setup button. The group patch buttons are replaced
with the channel list buttons. Channels that are included in the group display in green;
those not included are displayed in white. To add or remove a channel from the group,
press the channel button. For multi-frequency channels, the current channel frequency
selection is saved with the group. When the group is activated, the channel frequency is set
to that stored with the group and then the channels are patched.
To save the group setup and return to the Miscellaneous Menu, press the Save Setup
button. To cancel the setup, press the Cancel button. Further groups are defined by
repeating the above steps.
Copy Files
Pressing this button brings a set of menu selections:
• SAVE SCNDRY CONFIG
• LOAD SCNDRY CONFIG
Saving the Current Console Configuration File
Use this selection to copy the configuration of the console from the PC hard disk to a
backup floppy disk. You may want to do this to archive the changes.
Insert a floppy disk on which you want the console configuration stored into the A: drive
on the console PC. Press SAVE SCNDRY CONFIG. Press COPY FILES to start the
copy process. The program copies the configuration files from the hard disk to the floppy
disk.
Loading a New Console Configuration from a Floppy Disk
Use this selection if you have entered a new console configuration using RDPS, on an
offline desktop or laptop PC, and wish to update the console operation.
Insert the floppy disk containing the RDPS configuration files into the A: drive on the
console PC. Press LOAD SCNDRY CONFIG. Press COPY FILES to start the copy
process. The program copies the configuration files from the floppy to the hard disk.
Set Console Config (Number)
This selection requests the number of the configuration before resetting the console
program. It is necessary to set the correct configuration number to ensure that the console
program loads the correct configuration files.